88081
ADV_50_133
Ordnance Factory Medak
The General Manager
Yeddumailaram, Medak District
Medak
Telangana
502205
Name
Code
Quantity
Approx Value
Select
FORGINGS UPTO 30 TO 40 Kgs.
Description
As per specification
Specification
As per specification
Testing / Inspection Facility
88082
ADV_19_121
Ordnance Factory Bhandara
The Cheif General Manager OFB
Bhandara
Bhandara
Maharashtra
441906
Name
Code
Quantity
Approx Value
Select
QUICK LIME
Description
QUICK LIME IN POWDER FORM AS PER SPCN.IS:1540 (PART-I)1980 REAFFIRMED 2020 FOR GRADE'C'TOTAL ALKALIN- ITY SHOULD BE 80%.MIN.AVAILABLE LIME AS CaO 65% BELOW WHICH THE MATERIAL WILL BE REJECTED(TOTAL ALKAINITY TOBE TESTED AS PER SPECN BF-1.11) QTY OF SAMPLE 1000 GMS FOR EACH TEST.
Specification
QUICK LIME IN POWDER FORM AS PER SPCN.IS:1540 (PART-I)1980 REAFFIRMED 2020 FOR GRADE'C'TOTAL ALKALIN- ITY SHOULD BE 80%.MIN.AVAILABLE LIME AS CaO 65% BELOW WHICH THE MATERIAL WILL BE REJECTED(TOTAL ALKAINITY TOBE TESTED AS PER SPECN BF-1.11) QTY OF SAMPLE 1000 GMS FOR EACH TEST.
Testing / Inspection Facility
QUICK LIME IN POWDER FORM AS PER SPCN.IS:1540 (PART-I)1980 REAFFIRMED 2020 FOR GRADE'C'TOTAL ALKALIN- ITY SHOULD BE 80%.MIN.AVAILABLE LIME AS CaO 65% BELOW WHICH THE MATERIAL WILL BE REJECTED(TOTAL ALKAINITY TOBE TESTED AS PER SPECN BF-1.11) QTY OF SAMPLE 1000 GMS FOR EACH TEST.
10
Metric tonne(1000kg)
PRECISION MACHINING OF COMPONENTS
Description
As per drawing.
Specification
As per drawing.
Testing / Inspection Facility
SEATS FOR BMP AND ITS VARIANTS
Description
675-18-Cd3 675-60-Cd2 675-59-Cd3
Specification
675-18-Cd3 675-60-Cd2 675-59-Cd3
Testing / Inspection Facility
SEATS FOR BMP AND ITS VARIANTS
Description
675-18-Cd3 675-60-Cd2 675-59-Cd3
Specification
675-18-Cd3 675-60-Cd2 675-59-Cd3
Testing / Inspection Facility
PRECISION MACHINING AND FABRICATION COMPONENTS AND SUB ASSEMBLIES
Description
As per drawing
Specification
As per drawing
Testing / Inspection Facility
PRECISION MACHINING AND FABRICATION COMPONENTS AND SUB ASSEMBLIES
Description
As per drawing
Specification
As per drawing
Testing / Inspection Facility
88083
ADV_106_102
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name
Code
Quantity
Approx Value
Select
KAPOK INDIAN (SEMUL) VARIOUS
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
88084
ADV_508_127
Ordnance Factory Ambajhari
The Sr.General Manager,
Ambajhari
Ambajhari
Maharashtra
440021
88085
ADV_584_103
Metal and Steel Factory
The General Manager,
Ishapore
Ishapore
Ishapur, West Bengal
743144
88086
ADV_294_119
Machine Tool Proto Type Factory
The General Manager,
Ambarnath
Ambarnath
Ambernath, Maharashtra
421502
Name
Code
Quantity
Approx Value
Select
SKF Bearings & other Products
Description
As per Specification / Drawings / Requirements
Specification
As per Specification / Drawings / Requirements
Testing / Inspection Facility
SKF Bearings & other Products
Description
As per Specification / Drawings / Requirements
Specification
As per Specification / Drawings / Requirements
Testing / Inspection Facility
DUPLOMATIC Rotating Tool Holder - Model PRR-B-HT30-ER25/40-T (Make - Duplomatic Automazione) and ot
Description
As per Specification / Drawings / Requirements
Specification
As per Specification / Drawings / Requirements
Testing / Inspection Facility
Nozzle PZM Insert
Description
Drg.No. ERDL/1040 (Casting)
Specification
Drg.No. ERDL/1040 (Casting)
Testing / Inspection Facility
PZM Nozzle Casting Cum Machining Left and Right
Description
PZM NOZZLE CASTING CUM MACHINING LEFT & RIGHT AS PER DRG.NO.FOR LEFT NOZZLE PZM ERDL DRG.NO. 1040, DET-1 AMENDED ON DT.11-03-15,FOR RIGHT NOZZLE PZM ERDL DRG.NO.1040 ,DET-2 AMENDED ON DT.11-03-15 AND FOR CASTING NOZZLE PZM ERDL DRG.NO. 1040.
Specification
PZM NOZZLE CASTING CUM MACHINING LEFT & RIGHT AS PER DRG.NO.FOR LEFT NOZZLE PZM ERDL DRG.NO. 1040, DET-1 AMENDED ON DT.11-03-15,FOR RIGHT NOZZLE PZM ERDL DRG.NO.1040 ,DET-2 AMENDED ON DT.11-03-15 AND FOR CASTING NOZZLE PZM ERDL DRG.NO. 1040.
Drawing no.
ERDL. DRG NO.1040 DET-1 & ERDL. DRG. NO. 1040 DET-2
Testing / Inspection Facility
PZM NOZZLE CASTING CUM MACHINING LEFT & RIGHT AS PER DRG.NO.FOR LEFT NOZZLE PZM ERDL DRG.NO. 1040, DET-1 AMENDED ON DT.11-03-15,FOR RIGHT NOZZLE PZM ERDL DRG.NO.1040 ,DET-2 AMENDED ON DT.11-03-15 AND FOR CASTING NOZZLE PZM ERDL DRG.NO. 1040.
20
Number
88087
ADV_147_111
Ordnance Factory Ambernath
The Sr.General Manager,
Ambarnath
Ambarnath
Maharashtra
421502
Name
Code
Quantity
Approx Value
Select
SOLID CARBIDE DRILL/SLOT/STEP DRILL
Description
AS PER IS/BIS/REQUIREMENT
Specification
AS PER IS/BIS/REQUIREMENT
Testing / Inspection Facility
END MILL
Description
AS PER IS/BIS/REQUIREMENT
Specification
AS PER IS/BIS/REQUIREMENT
Testing / Inspection Facility
MACHINE TOOL
Description
AS PER IS/BIS/REQUIREMENT
Specification
AS PER IS/BIS/REQUIREMENT
Testing / Inspection Facility
GRINDING WHEELS
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
ABRASIVES
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
POWER TOOLS
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
DIAMOND TOOLS
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
CHARCOAL
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
HARD COKE
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
ALL TYPES OF COMPUTER STATIONERY & CONSUMABLES ITEMS
Description
AS PER REQUIREMENT
Specification
AS PER REQUIREMENT
Testing / Inspection Facility
CHARCOAL
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
ALOXIDE CLOTH BELT
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
ALOXIDE CLOTH ROLL
Description
AS PER IS/REQUIREMENT
Specification
AS PER IS/REQUIREMENT
Testing / Inspection Facility
88088
ADV_115_123
Ordnance Factory Dumdum
The General Manager,
Dum Dum
Dum Dum
Kolkata, West Bengal
700028
Name
Code
Quantity
Approx Value
Select
FERROUS MATERIAL
Description
AS PER IS, BS, ASTM ETC
Specification
AS PER IS, BS, ASTM ETC
Testing / Inspection Facility
NON FERROUS MATERIAL
Description
AS PER IS, BS, ASTM ETC
Specification
AS PER IS, BS, ASTM ETC
Testing / Inspection Facility
FORGED FIN BODY FOR 125MM HE.
Description
OFDC DRG.NO.F-124(d) , MATERIAL ALUMINIUM ALLOY B-95 OF GOST: 4784-74 OR ALTERNATIVE DTD 5024 IN WP CONDITION.
Specification
OFDC DRG.NO.F-124(d) , MATERIAL ALUMINIUM ALLOY B-95 OF GOST: 4784-74 OR ALTERNATIVE DTD 5024 IN WP CONDITION.
Testing / Inspection Facility
Cutting Tools & Tooling Aids (Make : TaeguTec India)
Description
As per Specification / Drawings / Requirements
Specification
As per Specification / Drawings / Requirements
Testing / Inspection Facility
H.S.S. Tools, Drills, Taps, Reamers & Spl. Toolings (Make : YG-1 Industries)
Description
As per Specification / Drawings / Requirements
Specification
As per Specification / Drawings / Requirements
Testing / Inspection Facility
6. Die & Punch
Description
As per IS & BS Specn.
Specification
As per IS & BS Specn.
Testing / Inspection Facility
5. Roller Shaft
Description
As per IS & BS Specn.
Specification
As per IS & BS Specn.
Testing / Inspection Facility
4. Base Plug
Description
IS : 742 - 1981 Alloy Zn A 14
Specification
IS : 742 - 1981 Alloy Zn A 14
Testing / Inspection Facility
1. Machining of Blank
Description
GOST B - 19032-73 Steel Gr.II I-OA.
Specification
GOST B - 19032-73 Steel Gr.II I-OA.
Testing / Inspection Facility
2. Nose Adaptor
Description
IS - 1570 Pt. II 1979 Gr. 20C8 in CD Condn.
Specification
IS - 1570 Pt. II 1979 Gr. 20C8 in CD Condn.
Testing / Inspection Facility
3. Bush (Pinaka)
Description
SAE - 4130 ESR Gr. Steel
Specification
SAE - 4130 ESR Gr. Steel
Testing / Inspection Facility
PACKING CRATE REQD.FOR CD-14
Description
DRG.NO. P-161(a)
Specification
DRG.NO. P-161(a)
Testing / Inspection Facility
PACKING CRATE REQD.FOR CD-1
Description
DRG.NO.CO.-42
Specification
DRG.NO.CO.-42
Testing / Inspection Facility
PACKING CRATE REQD.FOR CD-2
Description
DRG.NO.P-2(c)
Specification
DRG.NO.P-2(c)
Testing / Inspection Facility
PACKING CRATE. REQD.FOR THIMBLE OF CANDLE SMOKE
Description
DRG.NO. P-112(b)
Specification
DRG.NO. P-112(b)
Testing / Inspection Facility
BOX WOODEN, NO.P-21 REQD.FOR BTU-2211(450)
Description
DRG.NO.ARDE-2137
Specification
DRG.NO.ARDE-2137
Testing / Inspection Facility
BOX WOOD, NO. P-22 REQD.FOR TU-1111
Description
DRG.NO.ARDE-2186
Specification
DRG.NO.ARDE-2186
Testing / Inspection Facility
PAPER KRAFT AMMUNITION
Description
JSS - 8135 - 017:02
Specification
JSS - 8135 - 017:02
Testing / Inspection Facility
ELECTRICAL & MECHANICAL SAFETY SHOES
Description
AS PER REQUIREMENT
Specification
AS PER REQUIREMENT
Testing / Inspection Facility
SPINDLE BEARING FOR BTU-250
Description
DRG.NO.ARDE-9501-03
Specification
DRG.NO.ARDE-9501-03
Testing / Inspection Facility
SEALING RING FOR FUZE PERCUSSION DA5A
Description
PT.NO.QX-1009 IN F.C
Specification
PT.NO.QX-1009 IN F.C
Testing / Inspection Facility
MOULDING RING FOR 125MM HE
Description
OFDC S.K. NO. 1098c
Specification
OFDC S.K. NO. 1098c
Testing / Inspection Facility
ROLLER WASHER FOR TU 1111
Description
DRG.NO.ARDE-2139 DET.NO.29 IN F.C
Specification
DRG.NO.ARDE-2139 DET.NO.29 IN F.C
Testing / Inspection Facility
WASHER REAR FOR TU 1111
Description
DRG.NO.ARDE-2139 DET.NO.23 IN F.C
Specification
DRG.NO.ARDE-2139 DET.NO.23 IN F.C
Testing / Inspection Facility
WASHER FRONT FOR TU 1111
Description
DRG.NO.ARDE-2139 DET.NO.21 IN F.C
Specification
DRG.NO.ARDE-2139 DET.NO.21 IN F.C
Testing / Inspection Facility
BUSH FRONT FOR TU 1111
Description
DET.NO.25 IN F.C
Specification
DET.NO.25 IN F.C
Testing / Inspection Facility
BUSH REAR FOR TU 1111
Description
DET.NO.68 IN F.C
Specification
DET.NO.68 IN F.C
Testing / Inspection Facility
ADAPTER BLANKING FOR TU-1111
Description
DRG.NO.ARDE-2139 DET. NO.58 IN F.C
Specification
DRG.NO.ARDE-2139 DET. NO.58 IN F.C
Testing / Inspection Facility
88089
ADV_651_117
Small Arms Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
88090
ADV_752_132
Field Gun Factory Kanpur
The General Manager,
Kanpur
Kanpur
Uttar Pradesh
208009
Name
Code
Quantity
Approx Value
Select
STUD TRIGGER
Description
FGK DRG. NO. PH -2-3
Specification
FGK DRG. NO. PH -2-3
Testing / Inspection Facility
STUD STOP CYLINDER
Description
FGK DRG. NO. PH PH-2-2
Specification
FGK DRG. NO. PH PH-2-2
Testing / Inspection Facility
STUD HAMMER
Description
FGK DRG. NO. PH -2-4
Specification
FGK DRG. NO. PH -2-4
Testing / Inspection Facility
STOP CYLINDER
Description
FGK DRG. NO. PH -1-11
Specification
FGK DRG. NO. PH -1-11
Testing / Inspection Facility
SCREW STOCK
Description
FGK DRG. NO. PHMK-III-1-15
Specification
FGK DRG. NO. PHMK-III-1-15
Testing / Inspection Facility
SCREW STOCK
Description
FGK DRG. NO. PH -1-15
Specification
FGK DRG. NO. PH -1-15
Testing / Inspection Facility
SCREW SHIELD
Description
FGK DRG. NO. PH -1-16
Specification
FGK DRG. NO. PH -1-16
Testing / Inspection Facility
SCREW PLUNGER
Description
FGK DRG. NO. PH -1-26
Specification
FGK DRG. NO. PH -1-26
Testing / Inspection Facility
SCREW PLATE BODY
Description
FGK DRG. NO. PH -MK-III-1-15
Specification
FGK DRG. NO. PH -MK-III-1-15
Testing / Inspection Facility
SCREW PLATE BODY
Description
FGK DRG. NO. PH -1-19
Specification
FGK DRG. NO. PH -1-19
Testing / Inspection Facility