Items open for Registration

Search

Reset
No Advertisement No. Factory Location Items
67921 ADV_880_101 Ammunition Factory Khadki The Cheif General Manager
Kirkee
Kirkee
Maharastra
411003
Name Code Quantity Approx Value Select
TAIL UNIT 8 A TO DES. REF. CQA(A)/AMN/2906 PT. NO.ITV 26 SA WITH CAP
Description
CQA(A) 2324
Specification
CQA(A) 2324
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
NOTCHED COIL TO DES. REF. ARDE 1933 DET. NO. 3, PT. NO. ITV 169 SPECN. CQA(A) 2322
Description
CQA(A) 2322
Specification
CQA(A) 2322
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
OTHER SIMILAR PRECISION MACHINING COMPONENTS
Description
AS PER AFK SPECN.
Specification
AS PER AFK SPECN.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STRIKER SPRING DES. REF. NO. CIA/AMN/1799 DET NO. 7 PT. NO. ITW 68 SPECN. CQA(A) 1504
Description
CQA(A) 1504
Specification
CQA(A) 1504
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ALUMINIUM SLUG FOR 40MM MGL CASE AS PER AFK DRG. NO. AFK/SK-525-08
Description
DRG. NO. AFK/SK-525-08
Specification
DRG. NO. AFK/SK-525-08
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ADAPTER NOSE MORT. BOMB NO. 1 MK 1/L STEEL DES. REF. NO. DD(L) 11855 PT. NO. TV 44 SPECN. CQA(A) 235
Description
CQA(A) 2351
Specification
CQA(A) 2351
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PLUNGER TO CQA(A) DRG. NO. 04-44-79000-06111-4E
Description
CQA(A) DRG. NO. 04-44-79000-06111-4E
Specification
CQA(A) DRG. NO. 04-44-79000-06111-4E
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
IGNITION ELEMENT (EMPTY) TO DRG. NO. CQA(A)/AMN/3229 PT. NO. IQV 30A
Description
DRG. NO. CQA(A)/AMN/3229 PT. NO. IQV 30A
Specification
DRG. NO. CQA(A)/AMN/3229 PT. NO. IQV 30A
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STRIKER TO DES. REF. CIA/AMN/1799 DET. NO. 3 PT. NO. ITW 65 SPECN. CQA(A) 1504
Description
CQA(A) 1504
Specification
CQA(A) 1504
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SPACER RING TO CQA(A) SEALED DRG. NO. 04-749-130222-03.4E
Description
CQA(A) DRG. NO. 04-749-130222-03.4E
Specification
CQA(A) DRG. NO. 04-749-130222-03.4E
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
NOTCHED COIL TO DESIGNERS REF. ARDE 1933 DET. NO. 3 PT. NO. ITV 169 SPECN. CQA(A) 2322
Description
CQA(A) 2322
Specification
CQA(A) 2322
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67922 ADV_417_107 Gun and Shell Factory The General Manager,
Cossipore
Cossipore
Cossipore West Bengal
700002
Name Code Quantity Approx Value Select
COMPONENTS FOR AK- 630 GUN
Description
AS PER REQUIRED DRG.& SPECIFICATION
Specification
AS PER REQUIRED DRG.& SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
84MM GUN BARREL
Description
AS PER REQUIRED DRG.& SPECIFICATION
Specification
AS PER REQUIRED DRG.& SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
BIPOD ASSEMBLY FOR 84MM RL GUN
Description
AS PER REQUIRED DRG.& SPECIFICATION
Specification
AS PER REQUIRED DRG.& SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
DRUM FOR AK- 630 GUN
Description
AS PER REQUIRED DRG.& SPECIFICATION
Specification
AS PER REQUIRED DRG.& SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
COWL FAIRING FOR AK 630
Description
COWL(FAIRING) FOR AK- 630 GUN.
Specification
COWL(FAIRING) FOR AK- 630 GUN.
Manufacturing Technology
  • AS PER ATTACHMENT
Testing / Inspection Facility
  • AS PER ATTACHMENT
72 Number
67923 ADV_50_133 Ordnance Factory Medak The General Manager
Yeddumailaram, Medak District
Medak
Telangana
502205
Name Code Quantity Approx Value Select
LARYNGOSCOPE WITH THREE ADULT BLADES
Description
MAKE LARYNGOSCOPE ANAESTHETICS
Specification
MAKE LARYNGOSCOPE ANAESTHETICS
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
HEAD IMMOBILIZER MAKE ME BER srl VIA LANGHIRANO ITALY
Description
MODEL ART 625 XROS
Specification
MODEL ART 625 XROS
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
12V 24V 18 LTR REFRIGERATOR AC MODEL YAB 19L 1188
Description
MAKE HENG YANG ELECTRIC APPLIANCE CHINA
Specification
MAKE HENG YANG ELECTRIC APPLIANCE CHINA
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
LAERDAL SUCTION UNIT 12V 24V DC OPERATED
Description
MAKE LAERDAL MEDICAL AS NORWAY MODEL LSU
Specification
MAKE LAERDAL MEDICAL AS NORWAY MODEL LSU
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
EMERGENCY AND TRANSPORT VENTILATOR ALONG WITH OXYGEN PR REGULATOR SINGLE STAGE
Description
MAKE SIEM ITALY MODEL BA 2001 MIEL
Specification
MAKE SIEM ITALY MODEL BA 2001 MIEL
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CARDIAC MONITOR WITH NIBP WITH INVERTER
Description
MAKE NIHON KOHDEN JAPAN MODEL TEC 7731K
Specification
MAKE NIHON KOHDEN JAPAN MODEL TEC 7731K
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
105 MM MEDIUM RANGE INERT ROCKET (MRIR) EMPTY ASSLY. AS PER DRG. NO. NASK 989
Description
DRG. NO. NASK 989
Specification
DRG. NO. NASK 989
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SRIR (EMPTY) (TYPE E,C & H) TO DRG. NO. NASK 990/1 (PROV)
Description
DRG. NO. NASK 990/1
Specification
DRG. NO. NASK 990/1
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
105 MM LONG RANGE INERT ROCKET (LRIR) EMPTY ASSLY. AS PER DRG. NO. NASK 987
Description
DRG. NO. NASK 987
Specification
DRG. NO. NASK 987
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
OTHER SIMILAR PRECISION MACHINING COMPONENTS
Description
AS PER AFK SPECN.
Specification
AS PER AFK SPECN.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
TAIL UNIT 8A WITH CAP DES. REF. CQA(A)/AMN/2906 PT. NO. ITV 26SA SPECN. CQA(A) 2324
Description
CQA(A) 2324
Specification
CQA(A) 2324
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CUP TO DRG. NO. ERDL 1005 DET NO. 2
Description
DRG. NO. ERDL 1005 DET NO. 2
Specification
DRG. NO. ERDL 1005 DET NO. 2
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CONTACT TO DRG. NO. ARDE 2078 DET 31 PROV. SPECN. ARDE/SPECN/415 PARA 1 TO 2
Description
ARDE/SPECN/415
Specification
ARDE/SPECN/415
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CLOSING DISC TO DRG. NO. ERDL 1005 DET NO. 3
Description
DRG. NO. ERDL 1005 DET NO. 3
Specification
DRG. NO. ERDL 1005 DET NO. 3
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CLOSING DISC TO DRG. NO. ERDL 1005 DET NO. 8 DT. 19-11-09
Description
DRG. NO. ERDL 1005 DET NO. 8
Specification
DRG. NO. ERDL 1005 DET NO. 8
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
HALF CUP B DESIGNER REF NO. CIA/AMN/851 PT. NO. ISV 862
Description
DRG. NO. CIA/AMN/851 PT. NO. ISV 862
Specification
DRG. NO. CIA/AMN/851 PT. NO. ISV 862
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67924 ADV_978_112 Ordnance Factory Katni The General Manager,
Katni
Katni
Madhya Pradesh
483503
Name Code Quantity Approx Value Select
CUTTING TOOLS ( ALL TYPES )
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ALL TYPES OF NON FERRUS METAL
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ALL TYPES OF FERRROUS METAL
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STEEL MATERIALS (ALL TYPES)
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
WELDED TITANIUM TUBES
Description
AS PER SPECN. & DRG.
Specification
AS PER SPECN. & DRG.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STAINLESS STEEL SEAMLESS TUBES & PIPES
Description
AS PER SPECN. & DRG.
Specification
AS PER SPECN. & DRG.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STAINLESS STEEL WELDED TUBES & PIPES
Description
AS PER SPECN. & DRG.
Specification
AS PER SPECN. & DRG.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67925 ADV_377_130 Ordnance Equipment Factory Hazaratpur The General Manager,
Hazratpur
Hazratpur
Uttar Pradesh
283103
Name Code Quantity Approx Value Select
FOUR WAY JOINT FOR TEFS
Description
CQA(GS)/US/467(d)
Specification
CQA(GS)/US/467(d)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
THREE WAY JOINT FOR ROOF POLE
Description
CQA(GS)/US/467(d)
Specification
CQA(GS)/US/467(d)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
THREE WAY JOINT WITH BASE PLATE
Description
CQA(GS)/US/467(d)
Specification
CQA(GS)/US/467(d)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67926 ADV_44_113 Ordnance Factory Khamaria The Cheif General Manager
Khamaria
Khamaria
Madhya Pradesh
482005
Name Code Quantity Approx Value Select
PAPER LAMINATED GR. 1
Description
PAPER LAMINATED GR. 1 SIZE 0.25 TO 0.33 MM TH X 60.96 CM OR 91.44 CM WIDE IN ROLL TO SPECN:- IND/ME/786(C) DC NO 3754-ME DT. 12/12/02
Specification
PAPER LAMINATED GR. 1 SIZE 0.25 TO 0.33 MM TH X 60.96 CM OR 91.44 CM WIDE IN ROLL TO SPECN:- IND/ME/786(C) DC NO 3754-ME DT. 12/12/02
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67927 ADV_4_108 Ordnance Clothing Factory Shahjahanpur The General Manager,
Shahjahanpur
Shahjahanpur
Shahjahanpur, Uttar Pradesh
242001
Name Code Quantity Approx Value Select
FABRICATION OF KNITTING OF SOCKS FOR TRADE
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
AMMUNITION CONTAINER BOX C-55A (PLYWOOD)
Description
AMMN. CONTAINER BOX C 55A (PLYWOOD) FOR AMMN. CONT. ASSY 173A TO DRG.PT.NO. ISV 626A DC 37283-A DT. 30/06/2011 REFER WITH DRG.NO.PT.NO. ISV-557GA DC 37283-A DT. 30/06/2011
Specification
AMMN. CONTAINER BOX C 55A (PLYWOOD) FOR AMMN. CONT. ASSY 173A TO DRG.PT.NO. ISV 626A DC 37283-A DT. 30/06/2011 REFER WITH DRG.NO.PT.NO. ISV-557GA DC 37283-A DT. 30/06/2011
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SWITCH NO. 6 EMPTY ASSEMBLY OF 8 COMPONENTS
Description
DRG.NO. D.D.(L)-15270 D.C.NO. 36836-A DT. 14/06/02 EXCEPT SUB ASSEMBLY 2719
Specification
DRG.NO. D.D.(L)-15270 D.C.NO. 36836-A DT. 14/06/02 EXCEPT SUB ASSEMBLY 2719
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
14.5MM API COMPONENT: STEEL ENVELOPE FOR 14.5MM BULLET
Description
DRG.NO. TRD-2-1-2330 AND PENETRATOR OF BULLET COVERED WITH LEAD JECKET TO DRG.NO. TRD-1692 (FOR PENETRATOR) & TRD-1684 ALT (FOR JACKET)
Specification
DRG.NO. TRD-2-1-2330 AND PENETRATOR OF BULLET COVERED WITH LEAD JECKET TO DRG.NO. TRD-1692 (FOR PENETRATOR) & TRD-1684 ALT (FOR JACKET)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
14.5MM APIT COMPONENT:STEEL ENVELOPE FOR 14.5MM BULLET
Description
DRG.NO. TRD-2-1-2330 BULLET CORE TO DRG.NO. TRD-1693 BULLET JACKET TO DRG.NO. TRD-1684 & TRACER CAP TO (EMPTY) TO DRG.NO. TRD-1-2-2335
Specification
DRG.NO. TRD-2-1-2330 BULLET CORE TO DRG.NO. TRD-1693 BULLET JACKET TO DRG.NO. TRD-1684 & TRACER CAP TO (EMPTY) TO DRG.NO. TRD-1-2-2335
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STEEL ROD 29 MM
Description
SPECN: JSS-9510-01 SS/C-24A
Specification
SPECN: JSS-9510-01 SS/C-24A
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STRIKER & STIRRUP SPRING ASSEMBLY
Description
DRG.NO. 6171347 DC 28849-A DT. 23/04/68 CONSISTING OF STRIKER TO DRG.NO. 6171345 DC 36603-A DT. 13/10/99 & STIRRUP SPRING TO DRG.NO. 6160360 DC 37078-A DT. 13/11/06
Specification
DRG.NO. 6171347 DC 28849-A DT. 23/04/68 CONSISTING OF STRIKER TO DRG.NO. 6171345 DC 36603-A DT. 13/10/99 & STIRRUP SPRING TO DRG.NO. 6160360 DC 37078-A DT. 13/11/06
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SWITCH NO. 6 EMPTY ASSEMBLY OF 8 COMPONENTS
Description
DRG.NO. D.D.(L)-15270 D.C.NO. 36836-A DT. 14/06/02 EXCEPT SUB ASSEMBLY 2719
Specification
DRG.NO. D.D.(L)-15270 D.C.NO. 36836-A DT. 14/06/02 EXCEPT SUB ASSEMBLY 2719
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67928 ADV_956_142 Ordnance Factory Dehu Road The Cheif General Manager
Dehu Road
Dehu Road
Maharashtra
412101
Name Code Quantity Approx Value Select
COVER EMPTY FOR FLARE TRIP WIRE MK1/L ITEM NO. 9
Description
DRG.NO. DD(L) 13461-A/1, SHEET NO.1 DC 37167-A DT 05-04-08 SPECN NO.CQA(A)3807 (d) DC 37197-A DT.20/12/2008
Specification
DRG.NO. DD(L) 13461-A/1, SHEET NO.1 DC 37167-A DT 05-04-08 SPECN NO.CQA(A)3807 (d) DC 37197-A DT.20/12/2008
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SPRING WITH LINK FOR FLARE TRIP WIRE
Description
SPRING WITH LINK ITEM NO.11, CLAMP ITEM NO.10, WING NUT ITEM NO.14 TO DRG NO.DD(L) 13461-A/1 SHEET 1 DC NO. 37167-A DT 05/04/08 ARM WITH LOCATING BRRACKET TO DRG NO. DD(L)13461-A/1 SHEET 2 DC NO. 36632-A SPECN.NO CQA(A)3807 (d) DC 37197-A DT.20/12/2008
Specification
SPRING WITH LINK ITEM NO.11, CLAMP ITEM NO.10, WING NUT ITEM NO.14 TO DRG NO.DD(L) 13461-A/1 SHEET 1 DC NO. 37167-A DT 05/04/08 ARM WITH LOCATING BRRACKET TO DRG NO. DD(L)13461-A/1 SHEET 2 DC NO. 36632-A SPECN.NO CQA(A)3807 (d) DC 37197-A DT.20/12/2008
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
BODY & BOTTOM FOR FOG SIGNAL
Description
DRG. NO. OFDR/FOG SIGNAL/37/A1 AMDT NO. 185 DT. 24/5/2011
Specification
DRG. NO. OFDR/FOG SIGNAL/37/A1 AMDT NO. 185 DT. 24/5/2011
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67929 ADV_147_111 Ordnance Factory Ambernath The Sr.General Manager,
Ambarnath
Ambarnath
Maharashtra
421502
Name Code Quantity Approx Value Select
MANUFACTURING & SUPPLY OF CORRUGATED BOXES, ROLLS & SHEETS.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MANUFACTURING & SUPPLY OF CORRUGATED BOXES, ROLLS & SHEETS.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Assembly of Pumps.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Turning , Grinding, Milling.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Machining Components.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Strainers, Tanks, Mechanical Parts.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Sheet Metal Fabrication Items, Press Parts.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Assembly of Pumps.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Turning , Grinding, Milling.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Machining Components.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Strainers, Tanks, Mechanical Parts.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Sheet Metal Fabrication Items, Press Parts.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MANUFACTURE & SUPPLY OF ALUMINIUM MASTER ALLOYS, FERROUS & NON FERROUS ALLOYS.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MANUFACTURE & SUPPLY OF ALUMINIUM MASTER ALLOYS, FERROUS & NON FERROUS ALLOYS.
Description
AS PER OUR SPECIFICATION / REQUIREMENT.
Specification
AS PER OUR SPECIFICATION / REQUIREMENT.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67930 ADV_19_121 Ordnance Factory Bhandara The Cheif General Manager
Bhandara
Bhandara
Maharashtra
441906
Name Code Quantity Approx Value Select
Unit Load 155 Charge M4A2
Description
Drg No. 13646-4-0& CFA drawings.
Specification
Drg No. 13646-4-0& CFA drawings.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67931 ADV_259_138 Grey Iron Foundry The General Manager,
Jabalpur
Jabalpur
Jabalpur, Madhya Pradesh
482009
Name Code Quantity Approx Value Select
Machining of Cylinder for Aerial Bomb 100/120 Kgs
Description
As per Drawing & Specification
Specification
As per Drawing & Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Machining of Lifting Plug Casting
Description
As per Drawing & Specification
Specification
As per Drawing & Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Steel Castings
Description
As per specification & requirements
Specification
As per specification & requirements
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Steel Grits
Description
As per specification & requirements
Specification
As per specification & requirements
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Steel Shots
Description
As per specification & requirements
Specification
As per specification & requirements
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67932 ADV_651_117 Small Arms Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
Name Code Quantity Approx Value Select
MANUFACTURING OF FERROUS AND NON- FERROUS INVESTMENT CASTING COMPONAENTS
Description
AS PER DRAWING
Specification
AS PER DRAWING
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STEEL FORGING BLOCK GAS CYLINDER FOR LMG 5.56 MM
Description
AS PER DRAWING
Specification
AS PER DRAWING
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STEEL FORGING HAMMER FOR LMG 5.56 MM
Description
AS PER DRAWING
Specification
AS PER DRAWING
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
67933 ADV_115_123 Ordnance Factory Dumdum The General Manager,
Dum Dum
Dum Dum
Kolkata, West Bengal
700028
Name Code Quantity Approx Value Select
MAGAZINE FOR FUZE BODY
Description
Drg.Pt.No.IQX-12
Specification
Drg.Pt.No.IQX-12
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CAP FOR TU 8A
Description
Drg.ITV-184
Specification
Drg.ITV-184
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Case HEMK - I ( Modified ) L/A wood
Description
Drg No-IND/ME/29
Specification
Drg No-IND/ME/29
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Proceed