| 89681 |
ADV_115_123 |
Ordnance Factory Dumdum
|
The General Manager,
Dum Dum
Dum Dum
Kolkata, West Bengal
700028
|
| Name |
Code |
Quantity |
Approx Value |
Select |
PIN FOR TU1111
Description
DRG.NO. ARDE 2139 DET NO.27
Specification
DRG.NO. ARDE 2139 DET NO.27
Testing / Inspection Facility
|
|
|
|
|
COLLER FOR TU1111
Description
DRG.NO.ARDE 2139 DET NO.26
Specification
DRG.NO.ARDE 2139 DET NO.26
Testing / Inspection Facility
|
|
|
|
|
BUSH FRONT FOR TU1111
Description
DRG.NO.2139 DET.NO.25
Specification
DRG.NO.2139 DET.NO.25
Testing / Inspection Facility
|
|
|
|
|
WASHER REAR FOR TU1111
Description
DRG.NO.ARDE 2139 DET.NO.23
Specification
DRG.NO.ARDE 2139 DET.NO.23
Testing / Inspection Facility
|
|
|
|
|
RIB FRONT , MIDDLE & REAR FOR TU1111
Description
DRG.NO.ARDE 2139 DET NO.111
Specification
DRG.NO.ARDE 2139 DET NO.111
Testing / Inspection Facility
|
|
|
|
|
SUPPORTING RING FRONT, MIDDLE & REAR FOR TU1111
Description
DRG.NO.2139 DET. NO.8
Specification
DRG.NO.2139 DET. NO.8
Testing / Inspection Facility
|
|
|
|
|
LOCATING PIN FOR TU1111
Description
DRG.NO.ARDE 2139 DET.NO.6
Specification
DRG.NO.ARDE 2139 DET.NO.6
Testing / Inspection Facility
|
|
|
|
|
|
| 89682 |
ADV_475_104 |
Gun Carriage Factory
|
The General Manager,
Jabalpur
Jabalpur
Jabalpur,Madhya Pradesh
482011
|
|
| 89683 |
ADV_4_108 |
Ordnance Clothing Factory Shahjahanpur
|
The General Manager,
Shahjahanpur
Shahjahanpur
Shahjahanpur, Uttar Pradesh
242001
|
|
| 89684 |
ADV_701_110 |
Ordnance Parachute Factory
|
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208004
|
|
| 89685 |
ADV_619_128 |
Ordnance Factory Tiruchirapalli
|
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
|
|
| 89686 |
ADV_959_126 |
Ordnance Factory Varangaon
|
The Cheif General Manager
Varangaon
Varangaon
Maharashtra
425308
|
| Name |
Code |
Quantity |
Approx Value |
Select |
STEEL CORE FOR AK-47 BULLET
Description
DRG NO.VA7/PROV/009
Specification
DRG NO.VA7/PROV/009
Testing / Inspection Facility
|
|
|
|
|
STEEL INSERT FOR 5.56 MM INSAS
Description
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Specification
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Testing / Inspection Facility
|
|
|
|
|
LINK CARTG METALLIC BELT 7.62 MM M13
Description
CIA 4204(b) DC NO 36977-A DTD 24.8.2004
Specification
CIA 4204(b) DC NO 36977-A DTD 24.8.2004
Testing / Inspection Facility
|
|
|
|
|
LEAD ANTIMONY WIRE
Description
IS:1654-1992(THIRD REVISION), GRADE PBSB2
Specification
IS:1654-1992(THIRD REVISION), GRADE PBSB2
Testing / Inspection Facility
|
|
|
|
|
LEAD ANTIMONY ALLOY INGOT Pb:Sb - 98:2
Description
IS:1654-1992(THIRD REVISION), GRADE PBSB2
Specification
IS:1654-1992(THIRD REVISION), GRADE PBSB2
Manufacturing Technology
- Lead Antimony Alloy Melting Furnace
Testing / Inspection Facility
|
60 |
Metric tonne(1000kg) |
|
|
PIG LEAD
Description
IS:27-1992,GRADE PB 99.97%
Specification
IS:27-1992,GRADE PB 99.97%
Testing / Inspection Facility
|
|
|
|
|
STEEL CORE FOR AK-47 BULLET
Description
DRG NO.VA7/PROV/009
Specification
DRG NO.VA7/PROV/009
Testing / Inspection Facility
|
|
|
|
|
STEEL INSERT FOR 5.56 MM INSAS
Description
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Specification
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Testing / Inspection Facility
|
|
|
|
|
|
| 89687 |
ADV_294_119 |
Machine Tool Proto Type Factory
|
The General Manager,
Ambarnath
Ambarnath
Ambernath, Maharashtra
421502
|
| Name |
Code |
Quantity |
Approx Value |
Select |
Jelly Filled Telephone Cables
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Optical Fibre Cables
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Fluoroplastic
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
XLPE Cables
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
PVC Cables
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
LFH Cables
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Encoder & Display Unit
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Servo Panel and Distribution Panel
Description
As per Drawings / Specifications/ requirements
Specification
As per Drawings / Specifications/ requirements
Testing / Inspection Facility
|
|
|
|
|
Auto Transformer
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Gear Box Planetory
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
AC Servo Motors
Description
As per Drawings / Specifications / requirements
Specification
As per Drawings / Specifications / requirements
Testing / Inspection Facility
|
|
|
|
|
Cavalier AC Servo Power Supply
Description
As per Drawings / Specifications/ requirements
Specification
As per Drawings / Specifications/ requirements
Testing / Inspection Facility
|
|
|
|
|
A.C. Servo Drive Cavalier MK-II
Description
As per Drawings / Specifications/ requirements
Specification
As per Drawings / Specifications/ requirements
Testing / Inspection Facility
|
|
|
|
|
|
| 89688 |
ADV_361_134 |
High Energy Projectile Factory
|
The Cheif General Manager
Trichy
Trichy
Trichy, Tamil Nadu
620025
|
| Name |
Code |
Quantity |
Approx Value |
Select |
EQUIPMENT INCORPORATING SYSTEMS
Description
AS PER CUSTOMER REQUIREMENT
Specification
AS PER CUSTOMER REQUIREMENT
Testing / Inspection Facility
|
|
|
|
|
VENTILATION / EXHAUST SYSTEMS
Description
AS PER CUSTOMER REQUIREMENT
Specification
AS PER CUSTOMER REQUIREMENT
Testing / Inspection Facility
|
|
|
|
|
VARIOUS INDUSTRIAL FANS
Description
AS PER CUSTOMER REQUIREMENT
Specification
AS PER CUSTOMER REQUIREMENT
Testing / Inspection Facility
|
|
|
|
|
VARIOUS LOCTITE PRODUCTS
Description
LOCTITE SPECIFICATION
Specification
LOCTITE SPECIFICATION
Testing / Inspection Facility
|
|
|
|
|
ALL ITEMS OF ELECTROLATING MACHINERY
Description
AS PER CUSTOMER REQUIREMENT
Specification
AS PER CUSTOMER REQUIREMENT
Testing / Inspection Facility
|
|
|
|
|
STEEL CORE FOR 5.56 BULLET(MSMC)
Description
DRG NO.ARDE/0204-02-01-01-01-002-00DB
Specification
DRG NO.ARDE/0204-02-01-01-01-002-00DB
Testing / Inspection Facility
|
|
|
|
|
STEEL CORE FOR 7.62 MM PKT BULLET
Description
DRG NO.V//PROD/088
Specification
DRG NO.V//PROD/088
Testing / Inspection Facility
|
|
|
|
|
STEEL CORE FOR AK-47 BULLET
Description
DRG NO.VA7/PROV/009
Specification
DRG NO.VA7/PROV/009
Testing / Inspection Facility
|
|
|
|
|
STEEL INSERT FOR 5.56 MM INSAS
Description
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Specification
DRG NO. IQV 112 DCI NO 36853-A DTD 24.9.02
Testing / Inspection Facility
|
|
|
|
|
SEAL
Description
C OSL 125 - 1 601 7
Specification
C OSL 125 - 1 601 7
Testing / Inspection Facility
|
|
|
|
|
LATEX MOULD
Description
K PEN 105 - 1 015 1
Specification
K PEN 105 - 1 015 1
Testing / Inspection Facility
|
|
|
|
|
|
| 89689 |
ADV_147_111 |
Ordnance Factory Ambernath
|
The Sr.General Manager,
Ambarnath
Ambarnath
Maharashtra
421502
|
|
| 89690 |
ADV_658_135 |
Engine Factory Avadi
|
Chennai
Chennai
Chennai
Chennai, Tamil Nadu
600054
|
| Name |
Code |
Quantity |
Approx Value |
Select |
Steel Billets 200mm RCS +15 for Crankshaft Forging
Description
to Drg. No. 20-05-06-4
Specification
to Drg. No. 20-05-06-4
Testing / Inspection Facility
|
|
|
|
|
TAPE NYLON
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
|
|
|
|
|
|
|