Items open for Registration

Search

Reset
No Advertisement No. Factory Location Items
50961 ADV_619_128 Ordnance Factory Tiruchirapalli The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
Name Code Quantity Approx Value Select
Manufacturing and supply of Body Forging for 7.62mm Rifle
Description
AS PER DRAWING/SPECIFICATION
Specification
AS PER DRAWING/SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50962 ADV_44_113 Ordnance Factory Khamaria The Cheif General Manager
Khamaria
Khamaria
Madhya Pradesh
482005
Name Code Quantity Approx Value Select
BASE PLATE 7.8 MM FOR HEAT/TPT (6170444700)
Description
BASE PLATE 7.8 mm TO DRG NO F-1301-015080-K DC 36862-A DATE 11-11-02 SPECN:-F-1301-901520-L(b) (CQA-0305) DC NO.36766-ADT 14-7-2001
Specification
BASE PLATE 7.8 mm TO DRG NO F-1301-015080-K DC 36862-A DATE 11-11-02 SPECN:-F-1301-901520-L(b) (CQA-0305) DC NO.36766-ADT 14-7-2001
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SPRING 5209544 FOR HEAT-551 (9911357927)
Description
DRG.NO. 301100269
Specification
DRG.NO. 301100269
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ADOPTER BUSH FOR 81MM SMOKE GRENADE (9911358269)
Description
ADOPTER BUSH TO DRG.NO. 4-26941-007 DC NO. 35878 DTD. 20/12/94
Specification
ADOPTER BUSH TO DRG.NO. 4-26941-007 DC NO. 35878 DTD. 20/12/94
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50963 ADV_259_138 Grey Iron Foundry The General Manager,
Jabalpur
Jabalpur
Jabalpur, Madhya Pradesh
482009
Name Code Quantity Approx Value Select
Wooden Packing Crate for 100/120 Kg Aerial Bombs
Description
As per Drg. & Specification
Specification
As per Drg. & Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50964 ADV_701_110 Ordnance Parachute Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208004
Name Code Quantity Approx Value Select
Patch Oval With Trapezoidal Ring
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Patch Rubber with Handle
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Patch Round With D Rind
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
BRASS STRIP 24X0.70MM JSS:9535-02 (0710665177)
Description
BRASS STRIP 24+/-0.20 MM WIDE X 0.70+0.02 MM THICK IN COIL OF CONTINUOUS LENGTH TO SPECN:JSS-9535-02-2008 (REV.NO.3)
Specification
BRASS STRIP 24+/-0.20 MM WIDE X 0.70+0.02 MM THICK IN COIL OF CONTINUOUS LENGTH TO SPECN:JSS-9535-02-2008 (REV.NO.3)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
LEAD SHEET 915 X 3 MM IS:405-1992 (0800520003)
Description
LEAD SHEET 915 MM WIDE X 3 MM THICK IN ROLLED CONDITION IN LENGTH OF 5 MTR MINIMUM TO SPECIFICATION IS:405 (PT. II-1992)
Specification
LEAD SHEET 915 MM WIDE X 3 MM THICK IN ROLLED CONDITION IN LENGTH OF 5 MTR MINIMUM TO SPECIFICATION IS:405 (PT. II-1992)
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ALU ALLOY ROD 6 50 MM IS 733 24345 LF 0611500007
Description
ALUMINIUM ALLOY ROD 6.50 +/- 0.05 MM DIA IN ST. LENGTH OF 2.5 TO 3 MTRS TO SPECN:-IS-733-1983 REAFFIRMED 2006 (THIRD REVISION) DESIGN 24345 CONDITION : W
Specification
ALUMINIUM ALLOY ROD 6.50 +/- 0.05 MM DIA IN ST. LENGTH OF 2.5 TO 3 MTRS TO SPECN:-IS-733-1983 REAFFIRMED 2006 (THIRD REVISION) DESIGN 24345 CONDITION : W
Drawing no.
Manufacturing Technology
  • as per attached file
Testing / Inspection Facility
  • as per attached file
06 Ample
ALU ALLOY ROD 65MM IS733 GR24345 WP (0611503065)
Description
ALUMINIUM ALLOY ROD 65(+/-0.53) MM DIA IN LENGTH OF 1.0 TO 1.5 MTRS TO SPECN.IS:733-1983(3rd REVISION)(REAFFIRMED 2006)DESIG.24345 AND CONDITION WP
Specification
ALUMINIUM ALLOY ROD 65(+/-0.53) MM DIA IN LENGTH OF 1.0 TO 1.5 MTRS TO SPECN.IS:733-1983(3rd REVISION)(REAFFIRMED 2006)DESIG.24345 AND CONDITION WP
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
ALU ALLOY ROD 31 75MM IS733 64430 W LF 0611503032
Description
ALUMINIUM ALLOY ROD 31.75 +/-0.14 MM DIA IN ST LENGTH OF 2-3 METERS.TO SPECN:-IS-733-1983 (REAFFIRMED 2006) (THIRDREVISION) DESIG 64430 "W" CONDITION.
Specification
ALUMINIUM ALLOY ROD 31.75 +/-0.14 MM DIA IN ST LENGTH OF 2-3 METERS.TO SPECN:-IS-733-1983 (REAFFIRMED 2006) (THIRDREVISION) DESIG 64430 "W" CONDITION.
Drawing no.
ALUMINIUM ALLOY ROD 31.75 +/-0.14 MM DIA IN ST LENGTH OF 2-3 METERS.TO SPECN:-IS-733-1983 (REAFFIRMED 2006) (THIRDREVISION) DESIG 64430 "W" CONDITION.
Manufacturing Technology
  • as per attached file
Testing / Inspection Facility
  • as per attached file
06 Kilogram
ALU ALLOY ROD 26.50MM IS733 24345WP (0611505027)
Description
ALUMINIUM ALLOY ROD 26.5 (+/-0.20) MM DIA IN STRAIGHT LENGTH 2.0 TO 3 MTR.TO SPECN. IS-733-1983 (3rd Rev) (REFFIRMED-2006) GRADE-24345 IN WP CONDITION OR BS:1474-1987 GRADE-2014A IN T6 CONDITION & CONFIRMING ELASTIC LIMIT-275 MPa Min. UTS-412 Mpa MIN.ELONGATION-12% MIN.BRENELL HARDNESS 105-130
Specification
ALUMINIUM ALLOY ROD 26.5 (+/-0.20) MM DIA IN STRAIGHT LENGTH 2.0 TO 3 MTR.TO SPECN. IS-733-1983 (3rd Rev) (REFFIRMED-2006) GRADE-24345 IN WP CONDITION OR BS:1474-1987 GRADE-2014A IN T6 CONDITION & CONFIRMING ELASTIC LIMIT-275 MPa Min. UTS-412 Mpa MIN.ELONGATION-12% MIN.BRENELL HARDNESS 105-130
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50965 ADV_453_115 Ordnance Factory Muradnagar The General Manager,
Muradnagar
Muradnagar
Uttar Pradesh
201206
Name Code Quantity Approx Value Select
MACHINING OF T.A. WASHER
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF T.A. BOLT M20 & 27
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF T.A. CLAMP
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF T.A. GUIDE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF T.A. SHOE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PLUG (MCD) 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PLUG FASTENING 250 KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PLUG DUMMY 250 KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF LUG HOUSING HOLDER 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF LUG HOUSING 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PLUG A/C 34
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF THRUSTER PLATE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF FORGING OF LUG-318
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF FORGING OF LUG-243
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF BASE TRANSIT FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATIONA
Specification
AS PER OFM SPECIFICATIONA
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF NOSE PLUG FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATIONA
Specification
AS PER OFM SPECIFICATIONA
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF FILLING PLUG FORGING FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATIONA
Specification
AS PER OFM SPECIFICATIONA
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF DETONATOR HOLDER FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF CONTAINER EXPLODER FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF RING NUT FOR 1000LB, 450KG, 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
VARNISH APC
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
RED OXIDE ZINK CHROMATE PRIMER JSS-8010-68
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PAINT RFU SEMIGLOSS/GLOSSY/MATT OF DIFFERENT SHEDE IS-138
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PAINT RFU SEMIGLOSS/GLOSSY/MATT OF DIFFERENT SHEDE IS-168
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF FORGING OF T.A. SHOE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF FORGING OF T.A. CLAMP
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
MACHINING OF T.A. LINK
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
RING NUT (MCD) 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
PROTECTING RING ASSY. 1000LB
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
LUG HOUSING ASSY 450KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
FILLING PLUG 450KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
LUG HOUSING 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
BASE TRANSIT (MCD) 1000LB
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
BASE TRANSIT (MCD) 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CONTAINER EXPLODER 1000LB
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
CONTAINER EXPLODER 250KG
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Plastic Antic Tip
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Plastic Buckle
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Spring Type Cylinder Plastic Stopper
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Non Returning Valve
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Inflation/Deflation Valve
Description
As per Specification
Specification
As per Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50966 ADV_106_102 Ordnance Equipment Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name Code Quantity Approx Value Select
Trade Fabrication of Belt Waist Modified
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
STRAPS WITH CONNECTING PIECE & BUCKLE COMPLETE FOR VALISES OFFICER MK-II COMPLETED
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Bag Nose Small Cotton Duck Depth 46.0 Cm Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Bag Nose Large Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Cover Cloth Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Cover Pad PGS Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Tent Shelter 3 Ton OL Mk-1 Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Shelter Portable No. 3 Black Smith Cover Side Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Tent Latrine Walls W/o Poles Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Rug Horse Arctic Large Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Rug Horse Arctic Medium Complete
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50967 ADV_658_135 Engine Factory Avadi Chennai
Chennai
Chennai
Chennai, Tamil Nadu
600054
Name Code Quantity Approx Value Select
High Pressure pipe line
Description
Sb 20-23-00-10
Specification
Sb 20-23-00-10
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
High Pressure pipe line
Description
SB 323-36-4
Specification
SB 323-36-4
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
High Pressure pipe line
Description
SB 323-35-4
Specification
SB 323-35-4
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
High Pressure pipe line
Description
SB 323-34-4
Specification
SB 323-34-4
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
High Pressure pipe line
Description
SB 323-33-4
Specification
SB 323-33-4
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Ventilation System of Crankcase
Description
SB 3342-00-8A
Specification
SB 3342-00-8A
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Air Distributor
Description
SB 310-30-6
Specification
SB 310-30-6
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Breather system Mounting
Description
SB 3342-00-21
Specification
SB 3342-00-21
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
50968 ADV_32_114 Ordnance Factory Dehradun The General Manager,
Dehra Dun
Dehra Dun
Uttaranchal
248008
Name Code Quantity Approx Value Select
GLASS PLATE ODD/C/958/1,GLASS-LK-105, (478656).
Description
As per required Specification
Specification
As per required Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
GLASS PLATE ODD/C/957/1,GLASS LK-105 (478656).
Description
As per required Specification
Specification
As per required Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
SET OF FINISHED OPTICS CONSISTING OF PRISM OPTICAL INSTRUMENT MCT-2954/1 AND MCT-2976/1
Description
As per required Specification
Specification
As per required Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Cylinder liner (Forging)
Description
303-07-22
Specification
303-07-22
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Cylinder liner (Cast Iron Alloy)
Description
303-07-26
Specification
303-07-26
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
OPTICAL GLASS EDF 648338 IN MULTIPLE SIZE 350MMX180X55 STRIAE GRD.A INCLUSION GRD.SMALL-B FINE ANNEALED SO THAT STRESS BIREFRIGENCE IS NOT MORE THAN 12 NM/CM, IS:1400 SUPPLIER SHALL PROVIDE MELT DATA SHEET ALONG WITH SUPPLY.
Description
As per required Specification
Specification
As per required Specification
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
Proceed