56401
ADV_903_131
Vehicle Factory Jabalpur
The Sr.General Manager,
Jabalpore
Jabalpore
Madhya Pradesh
482009
Name
Code
Quantity
Approx Value
Select
Forging for Steering Arm-215433856003-3
Description
As per specification / Drawings
Specification
As per specification / Drawings
Testing / Inspection Facility
56402
ADV_956_142
Ordnance Factory Dehu Road
The Cheif General Manager
Dehu Road
Dehu Road
Maharashtra
412101
Name
Code
Quantity
Approx Value
Select
Safety Pin Assembly
Description
Drg. No. ARDE 2024 Det No 28 Consisting of:(1)Strip (2)Pin(3)Flag Red(4)Safety Screw (5)Spring Ring to Drg. Nos.(1)ARDE 2024/29,(2)ARDE 2024/30,(3)31 (SHTS2),(4)32,5)34 Respectively With Circlip Light A75IS:3075/1975 Gd.10R2 and Multitooth Lock Washer B6-4 IS : 5371-1982 Spring Steel.
Specification
Drg. No. ARDE 2024 Det No 28 Consisting of:(1)Strip (2)Pin(3)Flag Red(4)Safety Screw (5)Spring Ring to Drg. Nos.(1)ARDE 2024/29,(2)ARDE 2024/30,(3)31 (SHTS2),(4)32,5)34 Respectively With Circlip Light A75IS:3075/1975 Gd.10R2 and Multitooth Lock Washer B6-4 IS : 5371-1982 Spring Steel.
Testing / Inspection Facility
Base Plate Assy. for Bomb 3Kg.Practice
Description
Drg. No.ARDE-2024 Det 10. Amended vide AL NO.650 Dated 16-3-90 Consisting of- I)Base Plate to Drg. No. ARDE 2024 Det. No.11II)Adapter to Drg. No. ARDE 2024 DET NO.12 Amended Vide AL650 Dt.14.03.90.
Specification
Drg. No.ARDE-2024 Det 10. Amended vide AL NO.650 Dated 16-3-90 Consisting of- I)Base Plate to Drg. No. ARDE 2024 Det. No.11II)Adapter to Drg. No. ARDE 2024 DET NO.12 Amended Vide AL650 Dt.14.03.90.
Testing / Inspection Facility
Nose Assy. for Bomb 3 Kg. Practice
Description
Drg. No. ARDE 2024/Det.1 Consisting of :(1) Nose to Drg. No. ARDE 2024 Det No.2 (2) Nose Cap-Ring Assy. to Drg No ARDE 2024 DET NO.3 SHT.1 (3) Tripod Spring to Drg. No. ARDE 2024 Det No.4(4) Striker to Drg. No. ARDE 2024 Det 5(5)Multi-Tooth Lock Washer B-6-4 to IS:5371/1982(F.R) (Comm)
Specification
Drg. No. ARDE 2024/Det.1 Consisting of :(1) Nose to Drg. No. ARDE 2024 Det No.2 (2) Nose Cap-Ring Assy. to Drg No ARDE 2024 DET NO.3 SHT.1 (3) Tripod Spring to Drg. No. ARDE 2024 Det No.4(4) Striker to Drg. No. ARDE 2024 Det 5(5)Multi-Tooth Lock Washer B-6-4 to IS:5371/1982(F.R) (Comm)
Testing / Inspection Facility
Flare Ground Indicating MK-I Yellow Empty Set
Description
Drg. No. ARM 1108 C-1 Consisting of-(1) Body Arm 1108 C2 (2) Screw Neck ARM 1108 B3 (3) Plug Cap ARM 1108 A5 (4) Screw Cap ARM 1108 A4 (5) Base & Spike ARM 1108 A6.
Specification
Drg. No. ARM 1108 C-1 Consisting of-(1) Body Arm 1108 C2 (2) Screw Neck ARM 1108 B3 (3) Plug Cap ARM 1108 A5 (4) Screw Cap ARM 1108 A4 (5) Base & Spike ARM 1108 A6.
Testing / Inspection Facility
56403
ADV_496_120
Ordnance Clothing Factory Avadi
The General Manager,
Avadi
Avadi
Avadi, Tamil Nadu
600054
Name
Code
Quantity
Approx Value
Select
Fabrication of various garments
Description
As per the Specification
Specification
As per the Specification
Testing / Inspection Facility
56404
ADV_453_115
Ordnance Factory Muradnagar
The General Manager,
Muradnagar
Muradnagar
Uttar Pradesh
201206
Name
Code
Quantity
Approx Value
Select
MACHINED T.A. BOLT M-27
Description
AS PER SPECIFICATION
Specification
AS PER SPECIFICATION
Testing / Inspection Facility
MACHINED T.A. BOLT M-20
Description
AS PER SPECIFICATION
Specification
AS PER SPECIFICATION
Testing / Inspection Facility
T.A. BOLT M-27
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
T.A. BOLT M-20
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
FORGING AND MACHINING OF T.A. CLAMP
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
FORGING AND MACHINING OF T.A. SHOE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
FORGING AND MACHINING OF T.A. GUIDE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
MACHINED T.A. CLAMP
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
MACHINED T.A. SHOE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
MACHINED T.A. GUIDE
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
T.A. BOLT M27
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
T.A. BOLT M20
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
RING NUT 1000LBS
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
PROTECTING RING ASSEMBLY 1000LBS
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
CONTAINER EXPLODER 1000LBS
Description
AS PER OFM SPECIFICATION
Specification
AS PER OFM SPECIFICATION
Testing / Inspection Facility
56405
ADV_478_122
Ordnance Cable Factory Chandigarh
The General Manager,
Chandigarh
Chandigarh
Chandigarh
160002
Name
Code
Quantity
Approx Value
Select
Wire PML OF DIFFERENT SIZES
Physical Verification needed
Description
Wire PML (Braid) of different sizes
Specification
TY 4833-002-08558606-95
Manufacturing Technology
As per attachment
As per attachment
As per attachment
As per attachment
As per attachment
Testing / Inspection Facility
As per attachment
As per attachment
As per attachment
As per attachment
As per attachment
15
Metre
WIRE OF DIAMETER 0.75 mm sq. TO 300 mm sq.
Description
AS PER RELEVENT SUPPLY ORDER
Specification
AS PER RELEVENT SUPPLY ORDER
Testing / Inspection Facility
56406
ADV_44_113
Ordnance Factory Khamaria
The Cheif General Manager
Khamaria
Khamaria
Madhya Pradesh
482005
Name
Code
Quantity
Approx Value
Select
PRF FOR 30MM AK-630 PRACTICE NAVAL AMMN. (9911358280)
Description
PLUG REPRESENTING FUZE (PRF) TO DRG.NO. NAI(J) 550/1/2 (P) FOR 30 MM AK-630 PRACTICE NAVAL AMMN.
Specification
PLUG REPRESENTING FUZE (PRF) TO DRG.NO. NAI(J) 550/1/2 (P) FOR 30 MM AK-630 PRACTICE NAVAL AMMN.
Testing / Inspection Facility
PRF FOR 30MM AK-630 PRACTICE NAVAL AMMN. (9911358280)
Description
PLUG REPRESENTING FUZE (PRF) TO DRG.NO. NAI(J) 550/1/2 (P) FOR 30 MM AK-630 PRACTICE NAVAL AMMN.
Specification
PLUG REPRESENTING FUZE (PRF) TO DRG.NO. NAI(J) 550/1/2 (P) FOR 30 MM AK-630 PRACTICE NAVAL AMMN.
Testing / Inspection Facility
ADOPTER BUSH FOR 81 MM SMOKE GRENADE (9911358269)
Description
ADOPTER BUSH TO DRG.NO. 4-26941-007 DC NO. 35878
Specification
ADOPTER BUSH TO DRG.NO. 4-26941-007 DC NO. 35878
Testing / Inspection Facility
56407
ADV_619_128
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
56408
ADV_106_102
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
56409
ADV_294_119
Machine Tool Proto Type Factory
The General Manager,
Ambarnath
Ambarnath
Ambernath, Maharashtra
421502
Name
Code
Quantity
Approx Value
Select
WINDING MACHINE GEN. ASSY.
Description
DRG.NO.VMT-SK-119-0000-10
Specification
DRG.NO.VMT-SK-119-0000-10
Testing / Inspection Facility
CENTER ASSY.
Description
DRG.NO.VMT-SK-119-16000-12
Specification
DRG.NO.VMT-SK-119-16000-12
Testing / Inspection Facility
STRUCTURE ASSY.
Description
DRG.NO.VMT-SK-119-7000-10
Specification
DRG.NO.VMT-SK-119-7000-10
Testing / Inspection Facility
PULLER ASSEMBLY DRG NO VMT SK 119 13000 10 FOR WINDING MACHINE 125MM SCCC AS PER PART LIST ENCLOSED Qty 01 Set
Physical Verification needed
Description
PULLER ASSY. DRG. NO. VMT-SK-119-13000-10. FOR WINDING MACHINE 125MM SCCC (AS PER PART LIST ENCLOSED), Qty: 01 Set
Specification
PULLER ASSY. DRG. NO. VMT-SK-119-13000-10. FOR WINDING MACHINE 125MM SCCC (AS PER PART LIST ENCLOSED), Qty: 01 Set
Drawing no.
VMT SK 119 13000 10
Manufacturing Technology
Firm must submit the details of Manufacturing Technologies and Inspection/Testing Facilities available with the firm for manufacturing the subject item. Quality assurance plan (IF ANY) related to production and inspection to be submitted in technical bid. List of Plant & Machineries required for manufacturing of subject item to be submitted.
Testing / Inspection Facility
Firm must submit the details of Manufacturing Technologies and Inspection/Testing Facilities available with the firm for manufacturing the subject item. Quality assurance plan (IF ANY) related to production and inspection to be submitted in technical bid. List of Plant & Machineries required for manufacturing of subject item to be submitted.
30
Set
PAPER ROLLER STAND ASSY.
Description
DRG.NO.VMT-SK-119-15000-11
Specification
DRG.NO.VMT-SK-119-15000-11
Testing / Inspection Facility
PIPE
Description
DRG. NO. 675-38-SB107SB
Specification
DRG. NO. 675-38-SB107SB
Testing / Inspection Facility
TIGHTENING RING FOR FUZE FB-40
Description
AS PER DRAWING
Specification
AS PER DRAWING
Testing / Inspection Facility
PLUG REAR
Description
DRG. NO. ITV-52
Specification
DRG. NO. ITV-52
Testing / Inspection Facility
COUPLING (DIE FORGING)
Description
DRG. NO. 118 765-12-438-3
Specification
DRG. NO. 118 765-12-438-3
Testing / Inspection Facility
RING BEARING OUTER
Description
DRG NO. 765-15-92
Specification
DRG NO. 765-15-92
Testing / Inspection Facility
AZIMUTH INDICATOR
Description
5203-10.HO5203-66. (AS PER DRAWING)
Specification
5203-10.HO5203-66. (AS PER DRAWING)
Testing / Inspection Facility
LENSES
Description
AS PER RELEVENT SUPPLY ORDER
Specification
AS PER RELEVENT SUPPLY ORDER
Testing / Inspection Facility
NON-AUTOCLAVED PRISMS
Description
AS PER RELEVENT SUPPLY ORDER
Specification
AS PER RELEVENT SUPPLY ORDER
Testing / Inspection Facility
AUTOCLAVED PRISMS
Description
AS PER RELEVENT SUPPLY ORDER
Specification
AS PER RELEVENT SUPPLY ORDER
Testing / Inspection Facility
56410
ADV_417_107
Gun and Shell Factory
The General Manager,
Cossipore
Cossipore
Cossipore West Bengal
700002
56411
ADV_651_117
Small Arms Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
56412
ADV_837_140
Ordnance Factory Itarsi
The Cheif General Manager
Itarsi
Itarsi
Madhya Pradesh
461122
Name
Code
Quantity
Approx Value
Select
FUNNEL WITH VALVES
Description
DRG.NO.OFI/2006/GMP/97
Specification
DRG.NO.OFI/2006/GMP/97
Testing / Inspection Facility
FUNNEL WITH VALVES
Description
DRG.NO.OFI/2006/GMP/97
Specification
DRG.NO.OFI/2006/GMP/97
Testing / Inspection Facility
SET OF CASTING FIXTURE
Description
DRG.NO.HEMRL/SRP/PHR/05.1/DET NO.01 TO 04
Specification
DRG.NO.HEMRL/SRP/PHR/05.1/DET NO.01 TO 04
Testing / Inspection Facility
SET OF CASTING MANDREL
Description
54/PINAKA/GMP/OFI DT.15-02-2014
Specification
54/PINAKA/GMP/OFI DT.15-02-2014
Testing / Inspection Facility
CONTROL MOULDS
Description
DRG.NO.HEMRL/SRP/PIN/CON/04.1
Specification
DRG.NO.HEMRL/SRP/PIN/CON/04.1
Testing / Inspection Facility
GENERATOR SMOKE NO. 5 MK-1 (EMPTY)
Description
DRG. NO. ARM 1023 D2 EMPTY CONSISTING OF 1) LID 2)BAFFLE PLATE 3) BODY 4) BOTTOM 5) SOLDERING TAG 6) TEAR OFF DISC SPECN. NO. DTD & P (AIR) 207/ARM-RAW MATERIAL AS PER SPECN. IS-1993-2006 (FOURTH REV.) COLD REDUCED ELECTROLYTIC TIN PLATE)
Specification
DRG. NO. ARM 1023 D2 EMPTY CONSISTING OF 1) LID 2)BAFFLE PLATE 3) BODY 4) BOTTOM 5) SOLDERING TAG 6) TEAR OFF DISC SPECN. NO. DTD & P (AIR) 207/ARM-RAW MATERIAL AS PER SPECN. IS-1993-2006 (FOURTH REV.) COLD REDUCED ELECTROLYTIC TIN PLATE)
Testing / Inspection Facility
EMPTY COMPONENTS FOR BASE BLEED IGNITER.
Description
1. PLUG IGNITR TO DRG.NO. 02676-300002A203 2. PROTECTIVE DISC.ASSEMBLY TO DRG.NO.02676-300001A203
Specification
1. PLUG IGNITR TO DRG.NO. 02676-300002A203 2. PROTECTIVE DISC.ASSEMBLY TO DRG.NO.02676-300001A203
Testing / Inspection Facility
IGNITER PERCUSSION ASSY(EMPTY) DAY
Description
DRG.NO.NAD 8611/32 AND DRG.NO.NAD-8611/20,21,22,& 33
Specification
DRG.NO.NAD 8611/32 AND DRG.NO.NAD-8611/20,21,22,& 33
Testing / Inspection Facility
IGNITOR PERCUSSION (EMPTY)
Description
DRG.NOS. NAD - 8611/14 TO 8611/24
Specification
DRG.NOS. NAD - 8611/14 TO 8611/24
Testing / Inspection Facility
SET OF 9 COMPONENTS FOR FLARE TRIP WIRE MK-1/L (EMPTY)
Description
DRG. NO DD(L) 13461-A/1 SHEET I CONSISTING OF ITEM NO.1,2,3,4,5,8,13,14 AND 20.SPECN.NO CQA(A) 3807 (d)
Specification
DRG. NO DD(L) 13461-A/1 SHEET I CONSISTING OF ITEM NO.1,2,3,4,5,8,13,14 AND 20.SPECN.NO CQA(A) 3807 (d)
Testing / Inspection Facility
TUBE FOR HAND FLARE
Description
DRG.NO. OFDR/CT/1/11/A3.
Specification
DRG.NO. OFDR/CT/1/11/A3.
Testing / Inspection Facility
TUBE ITEM.NO.6 FOR FLARE TRIP WIRE
Description
DRG.NO - DD(L) 13461A/1 SHEET NO.1
Specification
DRG.NO - DD(L) 13461A/1 SHEET NO.1
Testing / Inspection Facility
BODY & BOTTOM (ITEM NO. 1 & 2)
Description
DRG. NO. OFDR/FOG SIGNAL/37/A1 AMDT NO. 185 DT. 24/5/2011
Specification
DRG. NO. OFDR/FOG SIGNAL/37/A1 AMDT NO. 185 DT. 24/5/2011
Testing / Inspection Facility
PICKET WITH SIDE SPRONG ITEM.NO.15
Description
DRG.NO.DD(L)13461-A/1SHEET NO.2
Specification
DRG.NO.DD(L)13461-A/1SHEET NO.2
Testing / Inspection Facility
COVER EMPTY FOR FLARE TRIP WIRE MK 1/L ITEM NO.9
Description
DRG.NO.DD(L) 13461-A/1, SHEET NO.1 SPECN NO.CQA(A)3807 (d)
Specification
DRG.NO.DD(L) 13461-A/1, SHEET NO.1 SPECN NO.CQA(A)3807 (d)
Testing / Inspection Facility
FERRULE FOR 120MM ILLG.
Description
DRG. NO. ARDE 2097 PT NO ITV - 217
Specification
DRG. NO. ARDE 2097 PT NO ITV - 217
Testing / Inspection Facility
SPRING WITH LINK (ITEM N0.10,11&14)
Description
DRG NO.DD(L) 13461-A/1 SHEET1 DC NO.37167-A DT05/04/08 ARM WITH LOCATING BRRACKET TO DRG NO.DD(L)13461-A/1SHEET 2 SPECN.NO CQA(A)3807 (d)
Specification
DRG NO.DD(L) 13461-A/1 SHEET1 DC NO.37167-A DT05/04/08 ARM WITH LOCATING BRRACKET TO DRG NO.DD(L)13461-A/1SHEET 2 SPECN.NO CQA(A)3807 (d)
Testing / Inspection Facility
EYE BOLT FOR 120MM ILLG.
Description
DRG.NO.OFDR/FT-464/A4 SPECN.NO.CQA(A) 2321 (b)
Specification
DRG.NO.OFDR/FT-464/A4 SPECN.NO.CQA(A) 2321 (b)
Testing / Inspection Facility
COLLAR FOR 120MM ILLG.
Description
DRG.NO.ARDE 2011 DET 8 PT NO.ITV - 158 MATERIAL SPECN.IS 1570C-20 SPECN.NO.CQA (A) 2321 (b)
Specification
DRG.NO.ARDE 2011 DET 8 PT NO.ITV - 158 MATERIAL SPECN.IS 1570C-20 SPECN.NO.CQA (A) 2321 (b)
Testing / Inspection Facility
RING FOR 120MM ILLG.
Description
DRG. NO. ARDE 2011,DET 24 PART NO.ITV-152 DC (I)33655-A DATE 12-09-1984 MATL. STEEL TO SPECN. NO.IS: 1570C 40.
Specification
DRG. NO. ARDE 2011,DET 24 PART NO.ITV-152 DC (I)33655-A DATE 12-09-1984 MATL. STEEL TO SPECN. NO.IS: 1570C 40.
Testing / Inspection Facility
DELAY HOLDER FOR 120MM ILLG.
Description
DRG.NO. ARDE 2011 DET 11 PT NO.ITV 153 WITH NUT FOR DEALY HOLDER TO DRG.NO.ARDE 2011 DET 12 PT NO ITV 154 SPECN .NO CQA(A) 2321 (b)
Specification
DRG.NO. ARDE 2011 DET 11 PT NO.ITV 153 WITH NUT FOR DEALY HOLDER TO DRG.NO.ARDE 2011 DET 12 PT NO ITV 154 SPECN .NO CQA(A) 2321 (b)
Testing / Inspection Facility
WASHER CUPPED FOR 120MM ILLG.
Description
DRG.NO.ARDE-2011 DET. 15, PT.NO.ITV-145 SPECN: NO.CQA (A)2321 (b)
Specification
DRG.NO.ARDE-2011 DET. 15, PT.NO.ITV-145 SPECN: NO.CQA (A)2321 (b)
Testing / Inspection Facility