MOP.12 SHELLS 155MM B/T ON PELLET WITHOUT GRUMET TO DRG.NO:155-1000(M)(UNIT LOAD) CONSISTING OF PALLET TO DRG.NO.155-1210(M), FRAME ASSEMBLY TO DRG.NO.155- 1230(M) DCNO.37126-A,DT.25.7.07.
Specification
MOP.12 SHELLS 155MM B/T ON PELLET WITHOUT GRUMET TO DRG.NO:155-1000(M)(UNIT LOAD) CONSISTING OF PALLET TO DRG.NO.155-1210(M), FRAME ASSEMBLY TO DRG.NO.155- 1230(M) DCNO.37126-A,DT.25.7.07.
X RAY FILM SHEET 30 CM X 40 CM INDUSTRIAL INTERLEAVED,100SPEED,HIGH CONTRAST,ASTM CL.2 TECHNICAL REQUIREMENTS: THE FILM WILL BE USED FOR X-RAYING HIGH CALIBER HE FILLED SHELLS.FILM SHOULD BE ABLE TO DETECT FILLING DEFECT SUCH AS POROSITY,CAVITY,PIPING & CRACKS OF MINIMUM 0.1 SQ.MM WITH ENERGY SOURCES 320 KV,2 MeV,4 MeV & 6 MeV WITH X-RAY FILM AUTO PROCESSOR.
Specification
X RAY FILM SHEET 30 CM X 40 CM INDUSTRIAL INTERLEAVED,100SPEED,HIGH CONTRAST,ASTM CL.2 TECHNICAL REQUIREMENTS: THE FILM WILL BE USED FOR X-RAYING HIGH CALIBER HE FILLED SHELLS.FILM SHOULD BE ABLE TO DETECT FILLING DEFECT SUCH AS POROSITY,CAVITY,PIPING & CRACKS OF MINIMUM 0.1 SQ.MM WITH ENERGY SOURCES 320 KV,2 MeV,4 MeV & 6 MeV WITH X-RAY FILM AUTO PROCESSOR.
X-RAY FILM ROLL, WIDTH-17"x 200 FEET LENGTH, FILM SPEED-100. DIMENSION OF PAPER CYLINDER ON WHICH FILMS TO BE ROLLED: ID = 77+/-2.0 MM, OD = 90.0 MM MAX., LENGTH = 430+/-10.0 MM AND OVERALL OD OF X-RAY FILM ROLL = 150MM MAX.
Specification
X-RAY FILM ROLL, WIDTH-17"x 200 FEET LENGTH, FILM SPEED-100. DIMENSION OF PAPER CYLINDER ON WHICH FILMS TO BE ROLLED: ID = 77+/-2.0 MM, OD = 90.0 MM MAX., LENGTH = 430+/-10.0 MM AND OVERALL OD OF X-RAY FILM ROLL = 150MM MAX.
BAG 3 A/L CANVAS FOR AMMN.CONTAINER ASSEMBLY 148 A TO DRG.NO.ARDE-2125 DET NO.1 PT.NO.ISV 532A DC(I) 36238-A DT.13.02.97 PAD SHOULDER FOR BAG 3A PART NO. ISV 266 SA DC 35469-A. STRAP I/ISV 104 SA DC-35771-A STRAP II/ISV 105 SA DC-35771-A AND LINK ISV 1528 DC-36268-A DT.03. 04.97.
Specification
BAG 3 A/L CANVAS FOR AMMN.CONTAINER ASSEMBLY 148 A TO DRG.NO.ARDE-2125 DET NO.1 PT.NO.ISV 532A DC(I) 36238-A DT.13.02.97 PAD SHOULDER FOR BAG 3A PART NO. ISV 266 SA DC 35469-A. STRAP I/ISV 104 SA DC-35771-A STRAP II/ISV 105 SA DC-35771-A AND LINK ISV 1528 DC-36268-A DT.03. 04.97.
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
25
27110
Number
42645
OFBL/ADV/09
Ordnance Factory Bolangir
The Cheif General Manager
Bolangir
Bolangir
Orissa
767770
BRASS STRIP TO SIZE:18+/-0.2MM(W)* 0.7+/-0.01MM(T) TO BS:2870,CZ-106,1/4 HARD. OXIDIZATION, BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION: EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE=02 KGS IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 20 TO 30 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
Specification
BRASS STRIP TO SIZE:18+/-0.2MM(W)* 0.7+/-0.01MM(T) TO BS:2870,CZ-106,1/4 HARD. OXIDIZATION, BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION: EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE=02 KGS IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 20 TO 30 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
ALUMINIUM STRIP [SIZE:22+/-0.1(W) X 0.52+0.01(T) MM] TO IS:737-2008,DESG. 19500, CONDITION "O". OXIDIZATION,BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION:EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE= 01 KG IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 10 TO 15 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
Specification
ALUMINIUM STRIP [SIZE:22+/-0.1(W) X 0.52+0.01(T) MM] TO IS:737-2008,DESG. 19500, CONDITION "O". OXIDIZATION,BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION:EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE= 01 KG IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 10 TO 15 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
ALUMINIUM STRIP [SIZE: 20+/-0.1(W) X 0.25+0.01 (T) MM] TO IS:737, GR.19500, CONDITION "H2".OXIDIZATION, BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION:EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE= 01 KG IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 15 TO 20 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
Specification
ALUMINIUM STRIP [SIZE: 20+/-0.1(W) X 0.25+0.01 (T) MM] TO IS:737, GR.19500, CONDITION "H2".OXIDIZATION, BEND & DENT MARK SHOULD NOT BE PRESENT IN THE COIL/ROLL SURFACE [PACKING CONDITION:EACH ROLL OF STRIP SHOULD BE RAPPED WITH PROPER COTTON CLOTHES THEN IN POLYTHENE PACK AND AFTER THAT THESE ROLLS SHOULD BE KEPT IN WOODEN BOX WITH PROPER CUSHIONING/ SUPPORT] ADVANCE SAMPLE= 01 KG IN SINGLE COIL FORM, BULK TO BE SUPPLIED IN 15 TO 20 KGS IN SINGLE COIL FORM, NABL TEST CERTIFICATE REQUIRED.
FABRICATION OF SHORTS PC WHITE (MODIFIED).
SWO PART II No. 60240.
SPECIFICATION NO:
1) DIMENSION: AS PER SPECN NO. IND/TC/4568(b).
2) CERTIFIED SAMPLE: AS PER APPROVED SAMPLE.
NOTE:
A) CUT COMPONENTS & GARNITURE WILL BE SUPPLIED BY THE FACTORY
B) DRAWING & SAMPLE WILL BE PROVIDED AT THE TIME OF FABRICATION, IF REQUIRED.
FABRICATION OF CAP MAN’S DANGER BUILDING WHITE.
SPECIFICATION NO: JSS : 8405-14
SWO PART II No. 60129.
NOTE:
A) CUT COMPONENTS & GARNITURE WILL BE SUPPLIED BY THE FACTORY.
B) DRAWING & SAMPLE WILL BE PROVIDED AT THE TIME OF FABRICATION, IF REQUIRED.
SYNTHETIC RUBBER BASED ADHESIVE FOR JOINING OF COMPONENTS OF BOOT HIGH ANKLE DVS" ADHESIVE DUNLOP S-758 (DUNLOP)/FIXOBONDPC-70A(DENTRITE)/FEVICOLE SR-505(PIDILI
Specification
S.T.S
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
21
20266
Litre
42663
20170200/PV/0332/EOT/F
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001