Plastic Button Reversible 19 mm in Matching printed pattern ( Thermosetting)
Specification
Plastic Button Reversible 19 mm in Matching printed pattern ( Thermosetting)
Specification No- IS:1461 1984(second Revision) reaffirmed 2003, Except that shape & design as per annexure "A" attached and feel & finish as per sample held in the custody of OCFS. As per relevant clause of supplementary schedule no. CQA(GS)/SS/346(b)
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
TAPE NYLON THICK OG PFF SIZES FOR BAG KIT UNIVERSAL MARK-2 ONE SET CONSIST OF;(A) TAPE NYLON THICK OG 25MM=086 MTR, B) TAPE NYLON THICK OG 38 MM =5.10 MT, C) TAPE NYLON THICK 38MM=0.32 MTR)
Specification
XX
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
21
44128
Set
36251
3173000701
Small Arms Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
SPECIFICATION NO.: IS: 3255-1979 Except that :- i) In appearance shade finish and in other respects not
defined in this Specn. the material shall conform to the
sealed pattern held in the custody of the Controller,
CQAT&C, KANPUR. (ii) There shall be no presence of starch (iii) Scouring loss mild method is to be followed in lieu of severe method & shall not exceed 2% (Two percent). (iv) Sampling plan as per annexure (B) attached.
Packing and marking as per schedule No.CIT&C/PMS/65.
Specification
SPECIFICATION NO.: IS: 3255-1979 Except that :- i) In appearance shade finish and in other respects not
defined in this Specn. the material shall conform to the
sealed pattern held in the custody of the Controller,
CQAT&C, KANPUR. (ii) There shall be no presence of starch (iii) Scouring loss mild method is to be followed in lieu of severe method & shall not exceed 2% (Two percent). (iv) Sampling plan as per annexure (B) attached.
Packing and marking as per schedule No.CIT&C/PMS/65
Drawing no.
Manufacturing Technology
Testing / Inspection Facility
2101774710
3439
Metre
36268
20170519/PV/0973/EOT/F (EID 102MMETT17002126)
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Junction Box, ex Enclosure, Size: 200X230X110 in MM. To House Terminal Connectors 0.5 mm2 -25 Nos, having following Configuration. (A) Material Should be of Aluminum Alloy LM-9TF as per BS-1490-1908/DIN 1725, (Part-2) Grade Al SII0Mg/AISI-12Cu (Material No. 3.2383) or ASTM:625-95 alloy A360-0. The Castings Shall Comply with the requirements of IS:617-1994, Designation 4635 and shall be supplied in T6 Solution Heat Treated and Precipitation Treated Condition. B) Junction Boxes need to be Hydrostatic Tested after Assembly of all Connectors. The JBs should withstand without signs of damage or leakage external water pressure of 0.1 BAR for a Period of 2 Hours. C) The Junction Boxes should have Thread Inserts to avoid Spoiling of Threads Done on Aluminum alloys QTY: 5 NOS
Specification
Junction Box, ex Enclosure, Size: 200X230X110 in MM. To House Terminal Connectors 0.5 mm2 -25 Nos, having following Configuration. (A) Material Should be of Aluminum Alloy LM-9TF as per BS-1490-1908/DIN 1725, (Part-2) Grade Al SII0Mg/AISI-12Cu (Material No. 3.2383) or ASTM:625-95 alloy A360-0. The Castings Shall Comply with the requirements of IS:617-1994, Designation 4635 and shall be supplied in T6 Solution Heat Treated and Precipitation Treated Condition. B) Junction Boxes need to be Hydrostatic Tested after Assembly of all Connectors. The JBs should withstand without signs of damage or leakage external water pressure of 0.1 BAR for a Period of 2 Hours. C) The Junction Boxes should have Thread Inserts to avoid Spoiling of Threads Done on Aluminum alloys QTY: 5 NOS
Junction Box, ex Enclosure Size : 330X230X110 in mm. To House Terminal Connectors 0.5 mm2 -75 Nos having following configuration (A) Material Should be of Aluminum Alloy LM-9TF AS Per BS-1490-1908/DIN 1725,(Part-2) Grade Al SII0Mg/AISI-12Cu (Material No. 3.2383) or ASTM:625-95 alloy A360-0, the Castings shall comply with the requirements of IS:617-1994, Designation 4635 and shall be supplied in T6 Solution Heat Treated and Precipitation Treated Condition (B) Junction Box Need to be Hydrostatic Tested after Assembly of all Connectors. The JBs should withstand without Signs of Damage or Leakage External Water Pressure of 0.1 Bar for a Period of 2 Hours C) The Junction Box should have Thread Inserts to Avoid Spoiling of Threads Done on Aluminum Alloys - QTY: 6 NOS
Specification
Junction Box, ex Enclosure Size : 330X230X110 in mm. To House Terminal Connectors 0.5 mm2 -75 Nos having following configuration (A) Material Should be of Aluminum Alloy LM-9TF AS Per BS-1490-1908/DIN 1725,(Part-2) Grade Al SII0Mg/AISI-12Cu (Material No. 3.2383) or ASTM:625-95 alloy A360-0, the Castings shall comply with the requirements of IS:617-1994, Designation 4635 and shall be supplied in T6 Solution Heat Treated and Precipitation Treated Condition (B) Junction Box Need to be Hydrostatic Tested after Assembly of all Connectors. The JBs should withstand without Signs of Damage or Leakage External Water Pressure of 0.1 Bar for a Period of 2 Hours C) The Junction Box should have Thread Inserts to Avoid Spoiling of Threads Done on Aluminum Alloys - QTY: 6 NOS
SPECN.NO.: ADRDE/SPECN/1987/31.
appearance, workmanship, finish and in all other respects not defined in this ADRDE Sprcification the material shall conform to the sealed pattern held in the
custody of the Controller, CQAT&C, Kanpur.
Sampling plan and criteria of conformity.
As per anexure 11 (TC-8).
SELF EXTINGUISHING TYPE AND BULK/APPARENT DENSITY 15/20 KG PER CUBIC METER
TO SPECN: IS-4671-1984(FIRST REVISION) REAFFIRMED 1995 SIZE:265MMx 146MMx 12(-) 1 MM TYPE-I
Specification
SELF EXTINGUISHING TYPE AND BULK/APPARENT DENSITY 15/20 KG PER CUBIC METER TO SPECN: IS-4671-1984(FIRST REVISION) REAFFIRMED 1995 SIZE:265MMx 146MMx 12(-) 1 MM
SELF EXTINGUISHING TYPE AND BULK/APPARENT DENSITY 15/20 KG. PER CUBIC METER TO SPECN: IS-4671-1984(FIRST REVISION) REAFFIRMED 1995 SIZE:275MMx 142MMx 12(-) 1 MM TYPE 2
Machining & Moulding of Nozzle Rear as per Drg. No. SK-9746 & Annexure A1, Annexure A2, Appendix A2, Appendix A3 and Appendix B14 to Appendix B17 required for Stabilizer Assembly of Rocket Pinaka.