1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
a. (A) Essential Eligibility Criteria. The firm should essentially have following facilities: 1. Blast Furnace and LD Converter (Basic Oxygen Furnace) OR Electric ARC furnace OR Induction Furnace
b. Firm should be able to supply minimum 500 nos. to 650 nos. of Parted Steel Billets per heat batch.
c. Ladle Refining furnace along with Argon purging system.
d. Vacuum degassing furnace along with Argon purging system.
e. Continuous caster OR Bottom pouring ingot casting facilities.
f. Soaking Pits or Pre heating Furnaces.
g. Rolling mill to maintain reduction ratio of at least 6:1.
h. Annealing or Normalizing Furnaces.
i. Optical emission Spectrometer.
j. Carbon Sulphur Analyzer.
l. Temperature measuring facilities during melting/casting.
k. Mechanical test facilities, as applicable.
l. Metallography facilities for Micro and Macro Analysis.
m. Ultrasonic testing facilities with qualified Personnel.
SET OF BOMB BODY EMPTY ASSEMBALY TO DRG NO.0303 00 01 01 02 000 00PC & CONSISTING OF 29 COMPONENTS AND TO ARDESPECIFICATION NO.ARDE/SPECN/668 DATE DEC'2007 REV.3 DATE NOV.2015 FOR PRE-FRAG 100-120KG
Specification
SET OF BOMB BODY EMPTY ASSEMBALY TO DRG NO.0303 00 01 01 02 000 00PC & CONSISTING OF 29 COMPONENTS AND TO ARDESPECIFICATION NO.ARDE/SPECN/668 DATE DEC'2007 REV.3 DATE NOV.2015 FOR PRE-FRAG 100-120KG
COTTON FABRIC FOR S.D. PARACHUTE type II of IS:2970-1987 Reffirmed 2004 There shall be no presence of starch in appearance workmanship and finish and other respects not denined in the specification the material shall conform to the sealed pattern held in the custody of CQAT&C Kanpur. The bolt length/Roll length 40.00 Mtr. or above.
2.PACKING AND MARKING : As per relevant clause of specn.