SET OF BOMB BODY EMPTY ASSEMBALY TO DRG NO.0303 00 01 01 02 000 00PC & CONSISTING OF 29 COMPONENTS AND TO ARDESPECIFICATION NO.ARDE/SPECN/668 DATE DEC'2007 REV.3 DATE NOV.2015 FOR PRE-FRAG 100-120KG
Specification
SET OF BOMB BODY EMPTY ASSEMBALY TO DRG NO.0303 00 01 01 02 000 00PC & CONSISTING OF 29 COMPONENTS AND TO ARDESPECIFICATION NO.ARDE/SPECN/668 DATE DEC'2007 REV.3 DATE NOV.2015 FOR PRE-FRAG 100-120KG
COTTON FABRIC FOR S.D. PARACHUTE type II of IS:2970-1987 Reffirmed 2004 There shall be no presence of starch in appearance workmanship and finish and other respects not denined in the specification the material shall conform to the sealed pattern held in the custody of CQAT&C Kanpur. The bolt length/Roll length 40.00 Mtr. or above.
2.PACKING AND MARKING : As per relevant clause of specn.
Snap Fastener Top 7/7 & Bottom 7/7 in Four Parts (Cap of Top Covered with Dark Brown Sheeting)
Specification:- IS:4741-1968 (reaffirmed 2008) Unit – set contains 10 set Snap fastener 7/7 bottom in two parts and 12 set Snap fastener 7/7 Top in two parts are equal to 01 set
Specification
Snap Fastener Top 7/7 & Bottom 7/7 in Four Parts (Cap of Top Covered with Dark Brown Sheeting)
Specification:- IS:4741-1968 (reaffirmed 2008) Unit – set contains 10 set Snap fastener 7/7 bottom in two parts and 12 set Snap fastener 7/7 Top in two parts are equal to 01 set
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
Electrical Control Panel Complete with Accessories as per Annexure A QTY 1 No
Specification
Electrical Control Panel Complete with Accessories as per Annexure A QTY 1 No
Drawing no.
Manufacturing Technology
a) Loading of Components:- The panel of components including flat parts ( Doors, Rear Panels, Top & Bottom Covers, Gland Plates and Side Panels etc) . Compact Enclosures are loaded at this stage .
b) Pre Treatment- Stage I:- In this zone, all the oil grease and foreign impurities are cleaned.
c) Pre Treatment- Stage II:- This is done in different stages using water jets, which flush down all chemicals from stage I on the surface or the edges.
d) Pre treatment StageIII :- This is done in different stages using fresh DM water jets, which flush down all chemicals from stage II on the surface of edges.
e) Pretreatment stage IV- Here the panes are uniformly coated with a special Nano-ceramic coating bone rite NT-1 ( replacing the commonly used phosphating process) applied by high pressure jets.
f) Pre Treatment Stage V- This is done in different stages using water jets, which flush down all dissolved salts on the surface of the edges.
g) Pretreatment –Stage VI- In this final pre treatment
Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification
Following test as per Drg./QAP/Spec
1. Phosphate coating thickness
2. General purpose engineering equipment to measure dimensions like Micrometer, Vernier Caliper,
Height Gauge.
3. Thread gauge, Radius gauge
"Firm Should have the following in-house facility or arrange from outside and necessary tie up letter to be submitted.
i.e. Firm should have Chemical, Metallurgical & Mechanical testing Laboratory or tie up with other firms for the same."
"Firm Should have the following in-house facility or arrange from outside and necessary tie up letter to be submitted.
i.e. Firm should have Galvanizing & Chromatizing Facility or tie up with other firms for the same."
"Firm should have the following in-house manufacturing facilities for manufacturing of the item.
Milling Machine (Essential Criteria)"
"Firm should have the following in-house manufacturing facilities for manufacturing of the item.
Lathe Machine (Essential Criteria)"
"Firm should have the following in-house manufacturing facilities for manufacturing of the item.
Forging Facility-Open Die forging 500 Ton minimum capacity (Essential Criteria)"
"Firm Should have the following in-house facility or arrange from outside and necessary tie up letter to be submitted.
i.e. Firm should have Chemical, Metallurgical & Mechanical testing Laboratory or tie up with other firms for the same."
"Firm Should have the following in-house facility or arrange from outside and necessary tie up letter to be submitted.
i.e. Firm should have Galvanizing & Chromatizing Facility or tie up with other firms for the same."
Inspection Technology:
Following test as per Drg./QAP/Spec
1. General purpose engineering equipment to measure dimensions like Micrometer, Vernier Caliper,
Height Gauge.
i) Rubber Moulding
ii) Die making
In case tenderer is outsourcing any/some of the above activities, copy of the agreement with such source shall be submitted. The Rubber moulding facility is mandatory
(i) Standard Measuring Instruments & Gauges
(ii) Rubber Testing Facility with NABL/IRMRA accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced
i) Foundry Facility for Steel Casting
ii) Heat Treatment Facility
iii) Conventional/CNC machining
iv) Surface Treatment
In case tenderer is outsourcing any/some of the above activities, copy of agreement with such source shall be submitted. The machining facility is mandatory.
(i) Measuring Instruments/CMM & Gauges
(ii) Radiography Testing Facility duly certified by Government
(iii) Material Chemical & Physical facility with NABL accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced.
(i)Conventional /CNC machining Facility
(ii) Grinding Facility
In case tenderer is outsourcing any/some of the above activities, copy of agreement with such source shall be submitted. The machining facility is mandatory
(i) Standard Measuring Instruments & Gauges
(ii)Material Chemical & Physical facility with NABL accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced
(i) Heat treatment Facility
(ii) Coventional/CNC Machining
(iii)Grinding
iv) Surface Treatment Facility
v) Hard Chrome Plating
vi) Nitriding
vi) Gear Cutting
In case tenderer is outsourcing any/some of the above activities, copy of agreement with such source shall be submitted. The machining facility is mandatory
(i) Measuring Instruments/CMM & Gauges
(ii) Material Chemical & Physical facility with NABL accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced
i)Heat Treatment facility
ii) Conventional/CNC machining
iii) Welding
iv) Surface Treatment facility
In case tenderer is outsourcing any/some of the above activities, copy of agreement with such source shall be submitted. The machining facility is mandatory
i) Measuring Instruments/CMM & Gauges
ii) Material Chemical & Physical facility with NABL accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced
1. Chemical & Mechanical properties as per std. given drawing.
2. Dimensional inspection, for all dimensions given in the drawing & other parameter which are mentioned in relevant drawing.
PLASTIC SLIDE FASTENER OPEN END MEDIUM SPECIAL DUTY WHITE 58CM. SPECIFICATION:- IS:14181(PART 1-3) 2002 REAFFIRMED-2013.AS PER RELEVANT CLAUSE OF SPECIFICATION.AS PER RELEVANT CLAUSE OF SPECIFICATION
Specification
PLASTIC SLIDE FASTENER OPEN END MEDIUM SPECIAL DUTY WHITE 58CM. SPECIFICATION:- IS:14181(PART 1-3) 2002 REAFFIRMED-2013.AS PER RELEVANT CLAUSE OF SPECIFICATION.AS PER RELEVANT CLAUSE OF SPECIFICATION
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
(i) Foundry Facility for Aluminium Casting
(ii) Heat Treatment Facility
(iii) Conventional/CNC machining
(iv) Surface Treatment
In case tenderer is outsourcing any/some of the above activities, copy of agreement with such source shall be submitted. The foundry facility is mandatory.
(i) Measuring Instruments/CMM & Gauges
(ii) Radiography Testing facility duly certified by the Government
(iii) Material Chemical & Physical facility with NABL accreditation
Tenderer shall satisfy /declare the required inspection facilities are available either in house or outsourced.
71
8
Set
4893
EOI/PROVISIONAL/REGULARIZATION
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
1) Measuring Instruments/CMM & Gauges
2) Radiography Testing facility duly certified by the Government
3) Material Chemical & Physical facility with NABL accreditation
PAPER & BOARD CORRUGATED AMMUNITION DOUBLE FACED FINE FLUTE TO SPECN NO. JSS:8135-08:2008 (REV. NO.3)CONFIRMING TO STD SIZE- 787 MM X 559 MM X 5 MM THICK.
Specification
PAPER & BOARD CORRUGATED AMMUNITION DOUBLE FACED FINE FLUTE TO SPECN NO. JSS:8135-08:2008 (REV. NO.3)CONFIRMING TO STD SIZE- 787 MM X 559 MM X 5 MM THICK.
Inspection Technology:
Following test as per Drg./QAP/Spec
1. GSM testing facility
2.Chemical testing facility (Moisture content,PH of water extract, Water soluble chloride, Water
soluble sulphate, Fatty acids, Ash content%, Matter soluble in ether)
Inspection Technology:
Following test as per Drg./QAP/Spec
1. n-heptane test
2. General purpose engineering equipment to measure dimensions like Micrometer, Vernier Caliper,
Height Gauge.
Inspection Technology:
Following test as per Drg./QAP/Spec
1. General purpose engineering equipment to measure dimensions like Micrometer, Vernier Caliper,
Height Gauge.
Inspection Technology:
Following test as per Drg./QAP/Spec
1. Specific gravity
2. Flash point
3. Lead %
4. Evaporation %
5.PH of water extract
6. Water soluble chlorides
7. Water soluble sulphates
8. compatibility with explosive
9. Penetration.
CONNECTOR NO. CA 3981 FOR DETONATOR CABLE ELECTRIC 1B/L TODRG. PART NO. IQX 165 GF DC NO. 36953-A DT.10-03-04 ANDPVC SLEEVE INTERNAL DIAMETER 3.00 MM AND LENGTH 25 TO 30 MM
Specification
CONNECTOR NO. CA 3981 FOR DETONATOR CABLE ELECTRIC 1B/L TODRG. PART NO. IQX 165 GF DC NO. 36953-A DT.10-03-04 ANDPVC SLEEVE INTERNAL DIAMETER 3.00 MM AND LENGTH 25 TO 30 MM
Inspection Technology:
Following test as per Drg./QAP/Spec
1. Continuity test
2. General purpose engineering equipment to measure dimensions like Micrometer, Vernier Caliper,
Height Gauge.