No Advertisement No. Factory Location Items
2161 OFBH/2019/VR/0013 Ordnance Factory Bhusawal The General Manager,
Bhusawal
Bhusawal
Maharashtra
425203
Name Code Quantity Approx Value Select
HANDLE AND HANDLE CLIP SUB ASSEMBLY
Description
REQUIRED FOR METALLIC CONTAINER FOR TU33E
Specification
AS PER DRAWING NUMBER OFBH/SK/1535
Manufacturing Technology
  • SHEARING, FORMING, DRILLING, PUNCHING
Testing / Inspection Facility
  • AS PER QAP
01 10000 Number
2162 EOI13/PV/M1 Ordnance Factory Itarsi The Cheif General Manager
Itarsi
Itarsi
Madhya Pradesh
461122
Name Code Quantity Approx Value Select
GUANIDINE NITRATE
Physical Verification needed
Description
GUANIDINE NITRATE TO SPECN.JSS 6810-95:2018 (REV.NO 04)DC NO -6135- ME DT 10-05-2021.
Specification
GUANIDINE NITRATE TO SPECN.JSS 6810-95:2018 (REV.NO 04)DC NO -6135- ME DT 10-05-2021.
Drawing no.
Manufacturing Technology
  • Guanidine Nitrate is manufactured by heating Dicyandiamide confirming to IND/ME/878(Prov) with two equitant of Ammonium Nitrate confirming to IND/ME/86 degree C at 160 degree C.
Testing / Inspection Facility
  • Inspecti0on facility : Guanidine Nitrate and the packages in which it is packed shall be subject to inspection by and to the approval of the Quality Assurance Officer/Quality Assurance Authority
  • Testing facility/requirements : Samples taken from any portion of batch/lot/consignment of material shall confirm to the following test requirements Sl no. Characteristics Passing standard 1. Physical form Crystalline 2. Bulk Density, g/ml Min. 0.70 Max. 0.90 3. Melting point, oC Min. 210 Max. 214 4 Water soluble at 30 oC, % by mass Min. 15.10 5. Guanidine Nitrate , % by mass Min. 99 6. Ammonium Nitrate, % by mass Max. 0.48 7. Urea Nil
  • 8. Residue on ignition , % by mass Max. 0.02 9. Moisture content , % by mass Max. 0.48 10. Matter insoluble in water at 20 oC, % by mass Max . 0.50 11. Malamine, % by mass Max 0.10 12. pH of water extract Min. 5 Max. 6
1001256000 100174.60 Kilogram
2163 OLF/MM-2/T-1906010031 Opto Electronic Factory Dehradun
Dehradun
Dehradun
Dehradun, Uttaranchal
248008
Name Code Quantity Approx Value Select
9927089730 BULB
Physical Verification needed
Description
9927089730 BULB, MN 26-0.12-V-1 Drg No.SPECNNO:TY16-535-174-68 BULB, MN 26-0.12-V-1,SPECN.NO: TY16.535.174-68
Specification
9927089730 BULB, MN 26-0.12-V-1 Drg No.SPECNNO:TY16-535-174-68 BULB, MN 26-0.12-V-1,SPECN.NO: TY16.535.174-68
Drawing no.
9927089730 BULB, MN 26-0.12-V-1 Drg No.SPECNNO:TY16-535-174-68 BULB, MN 26-0.12-V-1,SPECN.NO: TY16.535.174-68
Manufacturing Technology
  • ELECTRONIC ITEM
Testing / Inspection Facility
  • ELECTRONIC ITEM
99 12130 Number
7441122612 LAMP KGM
Physical Verification needed
Description
7441122612 LAMP KGM 27-30-1 Drg No.TU16.88IKVA 675173.001 LAMP KGM 27-30-1 AS PER SPECN. NO. TU16.88IKVA675173.001
Specification
7441122612 LAMP KGM 27-30-1 Drg No.TU16.88IKVA 675173.001 LAMP KGM 27-30-1 AS PER SPECN. NO. TU16.88IKVA675173.001
Drawing no.
7441122612 LAMP KGM 27-30-1 Drg No.TU16.88IKVA 675173.001 LAMP KGM 27-30-1 AS PER SPECN. NO. TU16.88IKVA675173.001
Manufacturing Technology
  • ELECTRONIC ITEM
Testing / Inspection Facility
  • ELECTRONIC ITEM
74 209 Number
2164 O113-19 Ordnance Factory Dehradun The General Manager,
Dehra Dun
Dehra Dun
Uttaranchal
248008
Name Code Quantity Approx Value Select
GEN 3 18MM AUTOGATED IMAGE INTENSIFIERS TUBE WITH EMI PROTECTION DRG NO MCT 3550
Physical Verification needed
Description
GEN 3 18MM AUTOGATED IMAGE INTENSIFIERS TUBE WITH EMI PROTECTION DRG NO MCT 3550
Specification
AS PER SPECIFICATION
Drawing no.
Manufacturing Technology
  • AS PER SPECIFICATION
Testing / Inspection Facility
  • AS PER SPECIFICTAION
74 10 Number
ALUMINIUM ALLOY ROD 45MM DIA AS PER IS 733 1983 DESIGNATION 24345 CONDITION WP
Physical Verification needed
Description
ALUMINIUM ALLOY ROD 45MM(1-3/4”) DIA, AS PER IS: 733-1983, DESIGNATION -24345, CONDITION-WP
Specification
ALUMINIUM ALLOY ROD 45MM(1-3/4”) DIA, AS PER IS: 733-1983, DESIGNATION -24345, CONDITION-WP
Drawing no.
Manufacturing Technology
  • AS PER I.S SPECIFICATION
Testing / Inspection Facility
  • AS PER I.S SPECIFICATION
06 907 Kilogram
N M BRASS ROD 7 OBLIQUE 8 DIA TO SPECN I S 319 1989 GDE 1 HB Fe CONTENTS SHOULD NOT BE MORE THAN ZERO POINT ZERO FIVE PERCENT
Physical Verification needed
Description
N.M BRASS ROD 7/8” DIA TO SPECN I.S: 319-1989/GDE-1 HB (Fe CONTENTS SHOULD NOT BE MORE THAN 0.05%)
Specification
N.M BRASS ROD 7/8” DIA TO SPECN I.S: 319-1989/GDE-1 HB (Fe CONTENTS SHOULD NOT BE MORE THAN 0.05%)
Drawing no.
Manufacturing Technology
  • AS PER SPECIFICATION
Testing / Inspection Facility
  • AS PER SPECIFICATION
07 511 Kilogram
9001120874 BATTERY LITHIUM CELL
Physical Verification needed
Description
9001120874 BATTERY LITHIUM CELL 3.6V, SIZ E-AA AS PER SPECIFICATION NO. OLF/ A-1/SPEC. MAKE SHOULD BE OF RS/SAFT/TAD IRAN/TEKCELL ONLY.
Specification
9001120874 BATTERY LITHIUM CELL 3.6V, SIZ E-AA AS PER SPECIFICATION NO. OLF/ A-1/SPEC. MAKE SHOULD BE OF RS/SAFT/TAD IRAN/TEKCELL ONLY.
Drawing no.
9001120874 BATTERY LITHIUM CELL 3.6V, SIZ E-AA AS PER SPECIFICATION NO. OLF/ A-1/SPEC. MAKE SHOULD BE OF RS/SAFT/TAD IRAN/TEKCELL ONLY.
Manufacturing Technology
  • ELECTRONIC ITEM
Testing / Inspection Facility
  • ELECTRONIC ITEM
90 2183 Number
2165 111MMETT19001520 Ordnance Factory Ambernath The Sr.General Manager,
Ambarnath
Ambarnath
Maharashtra
421502
Name Code Quantity Approx Value Select
GRAPHITE BLOCK
Description
GRAPHITE BLOCK OF SIZE 550 + 5.0-0.0MM X 200 + 5.0-0.0MM X 325 + 5.0-0.0MM AS PER SCOPE OF SUPPLY ENCLOSED.
Specification
REFER FILE UPLOADED
Drawing no.
Manufacturing Technology
  • REFER FILE UPLOADED
Testing / Inspection Facility
  • REFER FILE UPLOADED
20 36 Number
ALUMINIUM ALLOY ROD 50MM DIA AS PER IS 733 1983 DESIGNATION 24345 CONDITION WP
Physical Verification needed
Description
ALUMINIUM ALLOY ROD 50MM DIA, AS PER IS: 733-1983, DESIGNATION -24345, CONDITION-WP
Specification
ALUMINIUM ALLOY ROD 50MM DIA, AS PER IS: 733-1983, DESIGNATION -24345, CONDITION-WP
Drawing no.
Manufacturing Technology
  • AS PER I.S. SPECIFICATION
Testing / Inspection Facility
  • AS PER I.S. SPECIFICATION
06 3877 Kilogram
BRASS ROD 9 OBLIQUE 16 INCH DIA TO SPEC IS 319 2007 GDE 1 HB HALF HARD
Physical Verification needed
Description
BRASS ROD 9/16 INCH DIA, TO SPEC -IS:319-2007 GDE-1 HB (HALF HARD)
Specification
BRASS ROD 9/16 INCH DIA, TO SPEC -IS:319-2007 GDE-1 HB (HALF HARD)
Drawing no.
Manufacturing Technology
  • AS PER SPECIFICATION
Testing / Inspection Facility
  • AS PER SPECIFICATION
07 590 Kilogram
2166 HVF/TE0102190209/2019-20/TA/CBOI/SD-OTE dt 03/02/2020 Heavy Vehicle Factory The Sr.General Manager,
Avadi
Avadi
Avadi, Tamil Nadu
600054
Name Code Quantity Approx Value Select
FLANGE 3806211059
Physical Verification needed
Description
FLANGE 3806211059
Specification
172.28.004-1/C
Drawing no.
172.28.004-1/C
Manufacturing Technology
  • AS PER VQC
Testing / Inspection Facility
  • AS PER QAP
38 250 Number
2167 TE NO 190401P2FO Gun Carriage Factory The General Manager,
Jabalpur
Jabalpur
Jabalpur,Madhya Pradesh
482011
Name Code Quantity Approx Value Select
9081008305 WHEEL CHOCK TO DRG NO GCF 50 41092
Physical Verification needed
Description
WHEEL CHOCK TO DRG. NO. GCF/50/41092
Specification
WHEEL CHOCK TO DRG. NO. GCF/50/41092
Drawing no.
Manufacturing Technology
  • As per tender document Annexure L & QAP
Testing / Inspection Facility
  • As per tender document Annexure L & QAP
90 192 Number
9081005873 MODIFIED BARREL CLEANING APPARATUS 155 MM GUN SYSTEM TO DRG NO GCF 50 41091
Physical Verification needed
Description
MODIFIED BARREL CLEANING APPARATUS (155 MM GUN SYSTEM) TO DRG NO.GCF/50/41091.
Specification
MODIFIED BARREL CLEANING APPARATUS (155 MM GUN SYSTEM) TO DRG NO.GCF/50/41091.
Drawing no.
Manufacturing Technology
  • As per tender document annexure L & QAP
Testing / Inspection Facility
  • As per tender document annexure L & QAP
90 10 Number
2168 3193000956 Small Arms Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
Name Code Quantity Approx Value Select
LEVER STUD CHANGE LEFT
Description
Lever stud change left DRG No.0204-03-04-02-15-002-00DA for JVPC 5.56mm (MIM Route)
Specification
Lever stud change left DRG No.0204-03-04-02-15-002-00DA for JVPC 5.56mm (MIM Route)
Drawing no.
0204-03-04-02-15-002-00DA
Manufacturing Technology
  • MIM ROUTE
Testing / Inspection Facility
  • 1) Chemical & Mechanical properties as per std. given drawing /Specification. 2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification
70 1722 Number
2169 128MMETT20001880 Ordnance Factory Tiruchirapalli The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
Name Code Quantity Approx Value Select
Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
Description
Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
Specification
Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
Drawing no.
Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
Manufacturing Technology
  • Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
Testing / Inspection Facility
  • Supply of Magazine 7 62mm 2A ICR 84A DC No 22245 SA Dt 15 07 93 consisting of ICR 91SA DC No 22756 SA Dt12 12 94 and ICR 90SA DC No 22540 SA Dt 20 05 94 and DS CAT No 1005 000344 DC No 26829 SA Dt 11 05 16 required for 7 62mm SLR
70 9375 Number
2170 110190301 Ordnance Parachute Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208004
Name Code Quantity Approx Value Select
FABRICATION OF HAP SUB ASSEMBLY
Description
FABRICATION OF HAP SUB ASSEMBLY (PACK COVER HAP, BAG INNER HAP, CARRYING BAG HAP, AND HARNESS HAP)
Specification
HAP Bag Inner: ADRDE/1283/A4(b) HAP Pack Cover: ADRDE/1283/A3(c) HAP Harness : ADRDE/1283/A2(f) HAP Carrying Bag: ADRDE/793/A12(f)
Drawing no.
Manufacturing Technology
  • As per Specification/drawing
Testing / Inspection Facility
  • As per Specification/drawing
2110025074 200 Set
METALLIC REEL
Description
METALLIC REEL
Specification
SPECN NO.ADRDE/786-SA-1(e)
Drawing no.
Manufacturing Technology
  • As per Specification/drawing
Testing / Inspection Facility
  • As per Specification/drawing
2110038026 284 Number
Fabric Nylon 66 48 GSM Undyed 95 Cm plus1 minus0
Description
Fabric Nylon 66, 48 GSM Undyed 95 Cm +1/-0
Specification
ADRDE/QMS/TDTM/F/2012/02 DATED 19 JAN 2012 and (i) The fabric shall have an initial spray rating of 80, 80, 70 minimum when tested as per AATCC 22 or equivalent test method. (ii) The manufacturer shall submit a certificate of compliance for each shipment indicating that fluorocarbon finish has been used.
Drawing no.
Testing / Inspection Facility
  • As per specification/drawing
2101222000 41979 Metre
2171 EOI/PROVISIONAL/REGULARIZATION Ordnance Equipment Factory The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name Code Quantity Approx Value Select
BAG CARRYING RESCUE COMPLETE
Description
BAG CARRYING RESCUE COMPLETE
Specification
DMSRDE/I&CS/95/426 (A)
Manufacturing Technology
  • AS PER SPECIFICATION
Testing / Inspection Facility
  • AS PER SPECIFICATION
21 AS PER TENDER Number
0321150115 STAINLESS STEEL TUBE 115X90X510 MM
Physical Verification needed
Description
0321150115 STAINLESS STEEL TUBE TO SIZE OUTER DIA 115.00 (+) (-) 1.00 MM X INNER DIA 90.00 (+) (-) 1.00 MM X 510.00 (+)2.00 MM LONG TO SPECN: AISI-316.OR, AISI-304
Specification
0321150115 STAINLESS STEEL TUBE TO SIZE OUTER DIA 115.00 (+) (-) 1.00 MM X INNER DIA 90.00 (+) (-) 1.00 MM X 510.00 (+)2.00 MM LONG TO SPECN: AISI-316.OR, AISI-304
Drawing no.
Manufacturing Technology
  • As per Specification & TE documents
Testing / Inspection Facility
  • As per Specification & TE documents
70 53 Number
0321150125 STAINLESS STEEL TUBE 125X100X830MM
Physical Verification needed
Description
0321150125 STAINLESS STEEL TUBE TO SIZE OUTER DIA 125.00 (+) (-) 1.00 - MM X INNER DIA 100.00 (+) (-) 1.00 MM X 830.00 (+) 2.00 MM LONG TO SPECN: AISI-316.OR,AISI-304.
Specification
0321150125 STAINLESS STEEL TUBE TO SIZE OUTER DIA 125.00 (+) (-) 1.00 - MM X INNER DIA 100.00 (+) (-) 1.00 MM X 830.00 (+) 2.00 MM LONG TO SPECN: AISI-316.OR,AISI-304.
Drawing no.
Manufacturing Technology
  • As per specification & TE documents
Testing / Inspection Facility
  • As per specification & TE documents
70 127 Number
FRAME ASSY TO 6206207012
Physical Verification needed
Description
FRAME ASSY TO DRG NO. 172.22.011CB-1CB
Specification
FRAME ASSY TO DRG NO. 172.22.011CB-1CB
Drawing no.
172.22.011CB-1CB
Testing / Inspection Facility
  • ATTACHED
62 44 Number
LF 7441123616 AUTOMATIC UNIT AS PER DRAWING 1360061500
Description
LF 7441123616 AUTOMATIC UNIT AS PER DRAWING 1360061500
Specification
LF 7441123616 AUTOMATIC UNIT AS PER DRAWING 1360061500
Drawing no.
LF 7441123616 AUTOMATIC UNIT AS PER DRAWING 1360061500
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 165 Number
LF 7441123615 IGNITION UNIT AS PER DRAWING 1360061200
Description
LF 7441123615 IGNITION UNIT AS PER DRAWING 1360061200
Specification
LF 7441123615 IGNITION UNIT AS PER DRAWING 1360061200
Drawing no.
LF 7441123615 IGNITION UNIT AS PER DRAWING 1360061200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 165 Number
LF 9001121829 COIL AS PER DRAWING 1360072000
Description
LF 9001121829 COIL AS PER DRAWING 1360072000
Specification
LF 9001121829 COIL AS PER DRAWING 1360072000
Drawing no.
LF 9001121829 COIL AS PER DRAWING 1360072000
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121828 COIL AS PER DRAWING 1360071900
Description
LF 9001121828 COIL AS PER DRAWING 1360071900
Specification
LF 9001121828 COIL AS PER DRAWING 1360071900
Drawing no.
LF 9001121828 COIL AS PER DRAWING 1360071900
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121827 COIL AS PER DRAWING 13671800
Description
LF 9001121827 COIL AS PER DRAWING 13671800
Specification
LF 9001121827 COIL AS PER DRAWING 13671800
Drawing no.
LF 9001121827 COIL AS PER DRAWING 13671800
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121826 COIL AS PER DRAWING 1360071700
Description
LF 9001121826 COIL AS PER DRAWING 1360071700
Specification
LF 9001121826 COIL AS PER DRAWING 1360071700
Drawing no.
LF 9001121826 COIL AS PER DRAWING 1360071700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121825 TRANSFORMER AS PER DRAWING 1360065200
Description
LF 9001121825 TRANSFORMER AS PER DRAWING 1360065200
Specification
LF 9001121825 TRANSFORMER AS PER DRAWING 1360065200
Drawing no.
LF 9001121825 TRANSFORMER AS PER DRAWING 1360065200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121824 COMBINATION BLOCK AS PER DRAWING 1360069300
Description
LF 9001121824 COMBINATION BLOCK AS PER DRAWING 1360069300
Specification
LF 9001121824 COMBINATION BLOCK AS PER DRAWING 1360069300
Drawing no.
LF 9001121824 COMBINATION BLOCK AS PER DRAWING 1360069300
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121823 COMBINATION BLOCK AS PER DRAWING 1360069100
Description
LF 9001121823 COMBINATION BLOCK AS PER DRAWING 1360069100
Specification
LF 9001121823 COMBINATION BLOCK AS PER DRAWING 1360069100
Drawing no.
LF 9001121823 COMBINATION BLOCK AS PER DRAWING 1360069100
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121822 FILTER AS PER DRAWING 1360065900
Description
LF 9001121822 FILTER AS PER DRAWING 1360065900
Specification
LF 9001121822 FILTER AS PER DRAWING 1360065900
Drawing no.
LF 9001121822 FILTER AS PER DRAWING 1360065900
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 9001121821 ROTERY TRANSFORMER AS PER DRAWING 1360062500
Description
LF 9001121821 ROTERY TRANSFORMER AS PER DRAWING 1360062500
Specification
LF 9001121821 ROTERY TRANSFORMER AS PER DRAWING 1360062500
Drawing no.
LF 9001121821 ROTERY TRANSFORMER AS PER DRAWING 1360062500
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
90 165 Number
LF 7441123619 Volatage Converter BPK242 As Per Drawing 1361195500
Description
LF 7441123619 Volatage Converter BPK242 As Per Drawing 1361195500
Specification
LF 7441123619 Volatage Converter BPK242 As Per Drawing 1361195500
Drawing no.
LF 7441123619 Volatage Converter BPK242 As Per Drawing 1361195500
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 139 Number
7441123618 ELECTRIC BLOCK AS PER DRAWING 1361190000
Description
7441123618 ELECTRIC BLOCK AS PER DRAWING NO. 1361190000
Specification
7441123618 ELECTRIC BLOCK AS PER DRAWING NO. 1361190000
Drawing no.
1361190000
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 335 Number
7441123621 VOLTAGE CONVERTER AS PER DRG 1367471300
Description
7441123621 VOLTAGE CONVERTER AS PER DRG. NO. 1367471300
Specification
7441123621 VOLTAGE CONVERTER AS PER DRG. NO. 1367471300
Drawing no.
1367471300
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 296 Number
LF 7441123620 POWER SUPPLY UNIT AS PER DRAWING 1366416200
Description
7441123620 POWER SUPPLY UNIT AS PER DRAWING NO. 1366416200
Specification
7441123620 POWER SUPPLY UNIT AS PER DRAWING NO. 1366416200
Drawing no.
1366416200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 357 Number
2172 MNF/BAFFLE/OFAJ Ordnance Factory Ambajhari The Sr.General Manager,
Ambajhari
Ambajhari
Maharashtra
440021
Name Code Quantity Approx Value Select
CONVERSION OF 125 MM FORGED SHELL
Description
CONVERSION OF 125 MM FORGED SHELL INTO SEMI-FINISHED SHELL AS PER DRG. NO SM – 1318 AND SCOPE OF WORK AS PER ANNEXURE A
Specification
CONVERSION OF 125 MM FORGED SHELL INTO SEMI-FINISHED SHELL AS PER DRG. NO SM – 1318 AND SCOPE OF WORK AS PER ANNEXURE A
Drawing no.
Manufacturing Technology
  • As per Bid
Testing / Inspection Facility
  • As per Bid
43 44433 Whole job
2173 OFK/2019/05/IV/3 Ordnance Factory Khamaria The Cheif General Manager
Khamaria
Khamaria
Madhya Pradesh
482005
Name Code Quantity Approx Value Select
84MM TWIN CONTAINER 520:8 PN 1202502 (LF- 9911358478)
Description
TWIN CONTAINER 520:82/ROUND PART NO.1202503
Specification
TWIN CONTAINER 520:82/ROUND PART NO.1202503
Drawing no.
TO OEM DRG.NO. 04110302/TRD DRG.NO.3.2.2568.
Manufacturing Technology
  • as per file attached
Testing / Inspection Facility
  • as per file attached
99 2100 Number
MAINTENANCE KIT CONSISTING 2 COMPONENTS TO 6206611108
Physical Verification needed
Description
MAINTENANCE KIT CONSISTING 2 COMPONENTS TO DRG NO. CQA(HV)SET/0001
Specification
MAINTENANCE KIT CONSISTING 2 COMPONENTS TO DRG NO. CQA(HV)SET/0001
Drawing no.
CQA(HV)SET/0001
Testing / Inspection Facility
  • ATTACHED
62 50 Number
LF 7440201116 RECEIVER FOR 1G46 T90 TO DRG AL5026010
Description
LF 7440201116 RECEIVER FOR 1G46(T-90) TO DRG NO. AL5.026.010
Specification
LF 7440201116 RECEIVER FOR 1G46(T-90) TO DRG NO. AL5.026.010
Drawing no.
LF 7440201116 RECEIVER FOR 1G46(T-90) TO DRG NO. AL5.026.010
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 143 Number
LF 7441123588 BOARD FOR BLOCK D AS PER DRAWING 1368089600
Description
LF 7441123588 BOARD FOR BLOCK D AS PER DRAWING NO.(CODE)1368089600
Specification
LF 7441123588 BOARD FOR BLOCK D AS PER DRAWING NO.(CODE)1368089600
Drawing no.
LF 7441123588 BOARD FOR BLOCK D AS PER DRAWING NO.(CODE)1368089600
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123593 DISCRIMINATOR SUB ASSY FOR BLOCK D AS PER DRAWING 1368059500
Description
LF 7441123593 DISCRIMINATOR SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368059500
Specification
LF 7441123593 DISCRIMINATOR SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368059500
Drawing no.
LF 7441123593 DISCRIMINATOR SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368059500
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123592 POWER UNIT SUB ASSY FOR BLOCK D AS PER DRAWING 1368058000
Description
LF 7441123592 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO. .(CODE)1368058000
Specification
LF 7441123592 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO. .(CODE)1368058000
Drawing no.
LF 7441123592 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO. .(CODE)1368058000
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123591 POWER UNIT SUB ASSY FOR BLOCK D AS PER DRAWING 1368057200
Description
LF 7441123591 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368057200
Specification
LF 7441123591 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368057200
Drawing no.
LF 7441123591 POWER UNIT SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368057200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123590 UNIT VV SUB ASSY FOR BLOCK D AS PER DRAWING 1368066700
Description
LF 7441123590 UNIT VV SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368066700
Specification
LF 7441123590 UNIT VV SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368066700
Drawing no.
LF 7441123590 UNIT VV SUB ASSY FOR BLOCK-D AS PER DRAWING NO.(CODE)1368066700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123589 CONTROL BLOCK SUB ASSY AS PER DRAWING 1368069400
Description
LF 7441123589 CONTROL BLOCK SUB ASSY AS PER DRAWING NO.(CODE)1368069400
Specification
LF 7441123589 CONTROL BLOCK SUB ASSY AS PER DRAWING NO.(CODE)1368069400
Drawing no.
LF 7441123589 CONTROL BLOCK SUB ASSY AS PER DRAWING NO.(CODE)1368069400
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123587 PROTECTION DEVICE AS PER DRAWING 1368069100
Description
LF 7441123587 PROTECTION DEVICE AS PER DRAWING NO.(CODE)1368069100
Specification
LF 7441123587 PROTECTION DEVICE AS PER DRAWING NO.(CODE)1368069100
Drawing no.
LF 7441123587 PROTECTION DEVICE AS PER DRAWING NO.(CODE)1368069100
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123586 PULSE SHAPER START AS PER DRAWING 1368063400
Description
LF 7441123586 PULSE SHAPER START AS PER DRAWING NO.(CODE)1368063400
Specification
LF 7441123586 PULSE SHAPER START AS PER DRAWING NO.(CODE)1368063400
Drawing no.
LF 7441123586 PULSE SHAPER START AS PER DRAWING NO.(CODE)1368063400
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123604 BOARD AS PER DRAWING 1368442200
Description
LF 7441123604 BOARD AS PER DRAWING NO.(CODE) 1368442200
Specification
LF 7441123604 BOARD AS PER DRAWING NO.(CODE) 1368442200
Drawing no.
LF 7441123604 BOARD AS PER DRAWING NO.(CODE) 1368442200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123603 BOARD AS PER DRAWING 1368470700
Description
LF 7441123603 BOARD AS PER DRAWING NO.(CODE) 1368470700
Specification
LF 7441123603 BOARD AS PER DRAWING NO.(CODE) 1368470700
Drawing no.
LF 7441123603 BOARD AS PER DRAWING NO.(CODE) 1368470700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123602 BOARD AS PER DRAWING 1368428400
Description
LF 7441123602 BOARD AS PER DRAWING NO.(CODE) 1368428400
Specification
LF 7441123602 BOARD AS PER DRAWING NO.(CODE) 1368428400
Drawing no.
LF 7441123602 BOARD AS PER DRAWING NO.(CODE) 1368428400
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123601 BOARD AS PER DRAWING 1368416600
Description
LF 7441123601 BOARD AS PER DRAWING NO.(CODE) 1368416600
Specification
LF 7441123601 BOARD AS PER DRAWING NO.(CODE) 1368416600
Drawing no.
LF 7441123601 BOARD AS PER DRAWING NO.(CODE) 1368416600
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123600 BOARD AS PER DRAWING 1368455200
Description
LF 7441123600 BOARD AS PER DRAWING NO.(CODE) 1368455200
Specification
LF 7441123600 BOARD AS PER DRAWING NO.(CODE) 1368455200
Drawing no.
LF 7441123600 BOARD AS PER DRAWING NO.(CODE) 1368455200
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123599 BOARD AS PER DRAWING 1368477300
Description
LF 7441123599 BOARD AS PER DRAWING NO.(CODE) 1368477300
Specification
LF 7441123599 BOARD AS PER DRAWING NO.(CODE) 1368477300
Drawing no.
LF 7441123599 BOARD AS PER DRAWING NO.(CODE) 1368477300
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123598 BOARD AS PER DRAWING 1368454300
Description
LF 7441123598 BOARD AS PER DRAWING NO.(CODE) 1368454300
Specification
LF 7441123598 BOARD AS PER DRAWING NO.(CODE) 1368454300
Drawing no.
LF 7441123598 BOARD AS PER DRAWING NO.(CODE) 1368454300
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123597 SHAPER AS PER DRAWING 1368405900
Description
LF 7441123597 SHAPER AS PER DRAWING NO.(CODE) 1368405900
Specification
LF 7441123597 SHAPER AS PER DRAWING NO.(CODE) 1368405900
Drawing no.
LF 7441123597 SHAPER AS PER DRAWING NO.(CODE) 1368405900
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123610 CONTROL BOARD AS PER DRAWING 1368782600
Description
LF 7441123610 CONTROL BOARD AS PER DRAWING NO.(CODE) 1368782600
Specification
LF 7441123610 CONTROL BOARD AS PER DRAWING NO.(CODE) 1368782600
Drawing no.
LF 7441123610 CONTROL BOARD AS PER DRAWING NO.(CODE) 1368782600
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123609 BOARD PCB AS PER DRAWING 1368782500
Description
LF 7441123609 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782500
Specification
LF 7441123609 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782500
Drawing no.
LF 7441123609 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782500
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123608 BOARD PCB AS PER DRAWING 1368782400
Description
LF 7441123608 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782400
Specification
LF 7441123608 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782400
Drawing no.
LF 7441123608 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782400
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123607 BOARD PCB AS PER DRAWING 1368782300
Description
LF 7441123607 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782300
Specification
LF 7441123607 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782300
Drawing no.
LF 7441123607 BOARD/P.C.B. AS PER DRAWING NO.(CODE) 1368782300
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123611 SPEED REGULATOR GOVERNOR PC AS PER DRAWING 1368782700
Description
LF 7441123611 (SPEED REGULATOR) GOVERNOR PC AS PER DRAWING NO.(CODE) 1368782700
Specification
LF 7441123611 (SPEED REGULATOR) GOVERNOR PC AS PER DRAWING NO.(CODE) 1368782700
Drawing no.
LF 7441123611 (SPEED REGULATOR) GOVERNOR PC AS PER DRAWING NO.(CODE) 1368782700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123606 THERMO REGULATOR THERMOSTATIC AS PER DRAWING 1368673600
Description
LF 7441123606 THERMO REGULATOR/THERMOSTATIC AS PER DRAWING NO.(CODE) 1368673600
Specification
LF 7441123606 THERMO REGULATOR/THERMOSTATIC AS PER DRAWING NO.(CODE) 1368673600
Drawing no.
LF 7441123606 THERMO REGULATOR/THERMOSTATIC AS PER DRAWING NO.(CODE) 1368673600
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123605 START TRIGGERING PULSE SHAPER AS PER DRAWING 1368673000
Description
LF 7441123605 START/TRIGGERING PULSE SHAPER AS PER DRAWING NO.(CODE) 1368673000
Specification
LF 7441123605 START/TRIGGERING PULSE SHAPER AS PER DRAWING NO.(CODE) 1368673000
Drawing no.
LF 7441123605 START/TRIGGERING PULSE SHAPER AS PER DRAWING NO.(CODE) 1368673000
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 93 Number
LF 7441123585 PCB ASSEMBLED UNIT AS PER DRAWING 1368840700
Description
LF 7441123585 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840700
Specification
LF 7441123585 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840700
Drawing no.
LF 7441123585 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 133 Number
LF 7441123584 PCB ASSEMBLED UNIT AS PER DRAWING1368841800
Description
LF 7441123584 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841800
Specification
LF 7441123584 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841800
Drawing no.
LF 7441123584 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841800
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 133 Number
LF 7441123581 PCB ASSEMBLED UNIT AS PER DRAWING 1368838900
Description
LF 7441123581 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368838900
Specification
LF 7441123581 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368838900
Drawing no.
LF 7441123581 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368838900
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 133 Number
LF 7441123582 PCB ASSEMBLED UNIT AS PER DRAWING 1368840600
Description
LF 7441123582 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840600
Specification
LF 7441123582 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840600
Drawing no.
LF 7441123582 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368840600
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 133 Number
LF 7441123583 PCB ASSEMBLED UNIT AS PER DRAWING 1368841000
Description
LF 7441123583 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841000
Specification
LF 7441123583 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841000
Drawing no.
LF 7441123583 PCB ASSEMBLED UNIT AS PER DRAWING NO.(CODE) 1368841000
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 133 Number
LF 7441123596 PCB ASSY FOR STABILIZER T90 AS PER DRAWING 1368657700
Description
LF 7441123596 PCB ASSY FOR STABILIZER (T-90) AS PER DRAWING NO. (CODE) 1368657700
Specification
LF 7441123596 PCB ASSY FOR STABILIZER (T-90) AS PER DRAWING NO. (CODE) 1368657700
Drawing no.
LF 7441123596 PCB ASSY FOR STABILIZER (T-90) AS PER DRAWING NO. (CODE) 1368657700
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123595 NORMALIZE UNIT PCB AS PER DRAWING 1368655400
Description
LF 7441123595 NORMALIZE UNIT (PCB) AS PER DRAWING NO. (CODE) 1368655400
Specification
LF 7441123595 NORMALIZE UNIT (PCB) AS PER DRAWING NO. (CODE) 1368655400
Drawing no.
LF 7441123595 NORMALIZE UNIT (PCB) AS PER DRAWING NO. (CODE) 1368655400
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 88 Number
LF 7441123594 CORRECTION SIGNAL AS PER DRAWING 1368656900
Description
7441123594 CORRECTION SIGNAL AS PER DRAWING NO. (CODE) 1368656900
Specification
7441123594 CORRECTION SIGNAL AS PER DRAWING NO. (CODE) 1368656900
Drawing no.
7441123594 CORRECTION SIGNAL AS PER DRAWING NO. (CODE) 1368656900
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 153 Number
PIPE HAND PUMP OIL TANK IAN 88 SA
Physical Verification needed
Description
PIPE,HAND PUMP/OIL TANK. IAN 88 SA
Specification
PIPE,HAND PUMP/OIL TANK. IAN 88 SA
Drawing no.
Manufacturing Technology
  • As per Drg
Testing / Inspection Facility
  • As per QAP
90 87 Number
LF 7440208426 REDUCTION GEAR AL6332080
Description
LF 7440208426 REDUCTION GEAR AL6.332.080
Specification
LF 7440208426 REDUCTION GEAR AL6.332.080
Drawing no.
LF 7440208426 REDUCTION GEAR AL6.332.080
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number
LF 7440208413 DRIVE AL6337172
Description
LF 7440208413 DRIVE AL6.337.172
Specification
LF 7440208413 DRIVE AL6.337.172
Drawing no.
LF 7440208413 DRIVE AL6.337.172
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number
LF 7440208419 SHAFT AL6308084
Description
LF 7440208419 SHAFT AL6.308.084
Specification
LF 7440208419 SHAFT AL6.308.084
Drawing no.
LF 7440208419 SHAFT AL6.308.084
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number
LF 7440208420 SHAFT AL6308086
Description
LF 7440208420 SHAFT AL6.308.086
Specification
LF 7440208420 SHAFT AL6.308.086
Drawing no.
LF 7440208420 SHAFT AL6.308.086
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number
LF 7440208437 DRIVE AL6337271
Description
LF 7440208437 DRIVE AL6.337.271
Specification
LF 7440208437 DRIVE AL6.337.271
Drawing no.
LF 7440208437 DRIVE AL6.337.271
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number
LF 7440208438 HOOD AL6437111
Description
LF 7440208438 HOOD AL6.437.111
Specification
LF 7440208438 HOOD AL6.437.111
Drawing no.
LF 7440208438 HOOD AL6.437.111
Manufacturing Technology
  • Manufacturing Technology
Testing / Inspection Facility
  • Testing / Inspection Facility
74 50 Number